background image

RECOMMENDED TOOLS AND MATERIALS

Putty Knife 

 

Regular Screwdriver  

Adjustable Wrench 

      Sealant 

 

Tape Measure

Hacksaw 

 

Wax Ring/Gasket 

 

Flexible Supply Tube 

      Closet Bolts  

Carpenters Level

1

   REMOVE OLD TOILET

a.  Close toilet supply valve and flush tank completely. Towel or sponge remaining water from tank and bowl.
b.  Disconnect and remove supply line. NOTE:

 If replacing valve, first shut off main water supply!

c.  Remove old mounting hardware, remove toilet and plug floor waste opening to prevent escaping sewer gases.
d.  Remove closet bolts from flange and clean away old wax, putty, etc. from base area.
     NOTE: 

Mounting surface must be clean and level

 before

 new toilet is installed!

SAVE FOR FUTURE USE

3

2

CLOSET FLANGE

CLOSET BOLTS

7 3 0 1 2 7 0 - 1 0 0   R e v .   A

A

CAUTION: PRODUCT IS FRAGILE. TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE!

P r o d u c t   n a m e s   l i s t e d   h e r e i n   a r e   t r a d e m a r k s   o f   A S   A m e r i c a ,   I n c .
©   A S   A m e r i c a ,   I n c .   2 0 0 8

NOTE: 

Pictures may not exactly define contour of china and components.

COMPACT CADET® 3 - 1.6 GPF ONE-PIECE TOILET
COMPACT CADET® 3 FloWise™ - 1.28 GPF ONE-PIECE TOILET

ROUGHING-IN DIMENSIONS:  

NOTE: 

Distance from wall to closet flange centerline must be as listed below:

5

4

INSTALL WAX SEAL

Invert toilet on floor (cushion to prevent damage), and 
install wax ring evenly around waste flange (horn), with 
tapered end of ring facing toilet. Apply a thin bead of 
sealant around toilet base.

POSITION TOILET ON FLANGE

a.  Unplug floor waste opening and install toilet on closet flange so bolts project
     through mounting holes.
b.  Loosely install retainer washers and nuts. Side of washers marked "THIS
     SIDE UP" 

must 

face up!

WAX RING

SEALANT

WASHER

NUT

FLANGE

BOLT

TH

IS SIDE UP

 

Model 2568 – Compact Elongated Right Height™ with Seat

Thank you for selecting American Standard – the benchmark of fine quality for over 100 years. To ensure this product is installed 
properly, please read these instructions carefully before you begin. (Certain installations may require professional help.) Also be sure 
your installation conforms to local codes.

!

INSTALL CLOSET BOLTS

Install closet bolts in flange channel, turn 90°, and slide 
into place 6" (152 mm) apart and parallel to wall.

724mm

(28-1/2)

159mm

(6-1/4)

16 ± 6mm
(5/8 ± 1/4)

419mm

(16-1/2)

292mm

(11-1/2)

267mm

(10-1/2)

724mm

(28-1/2)

 381mm

(15)

394mm

(15-1/2)

79mm

(3-1/8)

FINISHED WALL

422mm

(16-5/8)

305mm

(12)

C/L OF OUTLET

241mm

(9-1/2)

140mm

(5-1/2)

SUPPLY

AS 

REQ'D

*

FINISHED
FLOOR

C/L OF SEAT POST 
HOLES 140mm 
(5-1/2) CENTERS

INSTALLATION INSTRUCTIONS

Содержание Compact Cadet 3 2568

Страница 1: ...S NOTE Distance from wall to closet flange centerline must be as listed below 5 4 INSTALL WAX SEAL Invert toilet on floor cushion to prevent damage and install wax ring evenly around waste flange horn with tapered end of ring facing toilet Apply a thin bead of sealant around toilet base POSITION TOILET ON FLANGE a Unplug floor waste opening and install toilet on closet flange so bolts project thro...

Страница 2: ...INE These parts must be used as illustrated to insure water tight connection Use of existing coupling nut may result in water leakage Water supply tube or pipe must extend at least 1 2 inside threaded shank of valve does not apply to flanged tubing Use existing coupling nut and washer Use existing spiral cone washer Fluidmaster cone washer may not seal completely on spiral type supply line Captive...

Страница 3: ... any tank fitting damage caused by the use of cleaners containing chlorine calcium hypochlorite TANK LEVER S CLIP FLUSH VALVE TOP ARM NIPPLE Diagram 1 PARTS FOR WATER CONNECTION SEE STEP 9 CONE WASHER VALVE BODY FLAPPER THREADED SHANK SHANK WASHER COUPLING NUT HAND TIGHT ONLY FILL VALVE FLOAT CUP CRITICAL LEVEL MARK C L MUST BE 1 ABOVE OVERFLOW PIPE REFILL TUBE ADJUSTABLE HEIGHT WATER LEVEL ADJUST...

Страница 4: ...o tank overflow without being kinked or damaged b Supply valve partly closed b Open supply valve fully Be sure that proper supply tube size is used c Partially clogged trapway and or drain pipe and or vent c Remove obstruction Consult a plumber if necessary d Supply pressure too low d Normal supply pressure must be at least 20 psi Toilet leaks a Poor supply line connection a Review Step 8 of insta...

Отзывы: