background image

3475.300
3475.500

COLONY/COLONY SOFT

3

5

4

4

Certified to comply with ANSI A112.18.1

Installation

Instructions

Bidet Faucet and Transfer Valve

with SpeedConnect™ Drain

Congratulations on purchasing your American
Standard faucet with Speed Connect drain,  a
feature found only on American Standard faucets.

*Your new American Standard faucet is designed to work only with the SpeedConnect drain. 

To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.

M 9 6 8 7 9 5 R e v. 1 . 1      

Turn off hot and cold water
supplies before beginning.

CAUTION

1

BIDET FAUCET INSTALLATION

Replace UPPER GASKET 

(8) 

and WASHER 

(7)

 and

ESCUTCHEON (6) until it locks against internal stop.
Position the side threaded outlet rearward and
secure MOUNTING NUT

 (11)

.

Remove ESCUTCHEON 

(6)

, WASHER

 (7)

 and

UPPER GASKET 

(8)

from TRANSFER VALVE 

(9).

Insert TRANSFER VALVE 

(9)

 into the center forward

hole of BIDET.

COLD

HOT

BIDET

LEDGE

10

4

3a

3

8

9

1

5

2

6

SPRAY INSTALLATION

2

Assemble SPRAY BODY 

(1)

 to BIDET. Using putty, seal underside

of SPRAY BODY FLANGE 

(2)

 and secure with NUT 

(3)

.

Thread SPRAY CAP 

(9)

 onto SPRAY BODY 

(1)

.

Thread SPRAY HOSE 

(4)

 with SEAL WASHER 

(5)

 to SPRAY BODY 

(1)

.

Connect other end of HOSE 

(4)

 with SEAL WASHER 

(6)

 to side outlet

NIPPLE

(7)

 of the TRANSFER VALVE 

(8)

.

PUTTY

6

2

7

8

1

9

Tighten LOCKNUTS 

(1)

 with WRENCH 

(5)

 (supplied)

to secure VALVE BODIES 

(3, 3a)

.

Install LOCKNUT 

(1)

 and RUBBER WASHER 

(2)

 onto VALVE BODIES 

(3, 3a)

. From

under side of mounting surface, install VALVE BODY 

(3, 3a)

 through valve mounting

holes. Threads of VALVE BODY 

(3, 3a)

 should extent at least 5/16 of a inch above

mounting surface top. 

Fig. A.

Thread ESCUTCHEON 

(4)

onto VALVE BODIES 

(3, 3a)

until snug against internal stop. If necessary, adjust LOCKNUT 

(1)

.

Place RUBBER RING 

(10)

 into ESCUTCHEON 

(4)

.

MOUNTING

SURFACE

4

10

2
1

3, 3a

5/16''

MIN.

Fig. A.

11

Adjustable Wrench

 Screwdriver

Channel Locks

Required tools

Tubing Cutter

Phillips Screwdriver

Plumbers' Putty or

Caulking

7

1

Roughing-in

Dimensions

BIDET OUTLINE
IS SYMBOLIC

FINISHED
FLOOR

FINISHED
WALL

1-1/4 O.D. TAILPIECE

DOUCHE
SPRAY

2-1/8

DIA.

ADJ. 1-1/4

TO 2-1/4

3-7/8

5-1/2

1-3/8

DIA.

7/8 DIA.

1-1/4

MAX.

1-3/16

DIA.

2-1/4

DIA.

(C)

(H)

4-1/4

FOR GROUND JOINT
CONNECTION OR 1/2 "
O.D. SLIP (INLETS) 

REAR VIEW WITH

WALL REMOVED

TRANSFER VALVE

(FOR FLUSHING
RIM OR SPRAY)

8 TO 12

SpeedConnect Drain*

•  Fewer parts, installs in less time
•  Never needs adjustment
•  Guaranteed to seal properly the first time, every time.

Содержание COLONY 3475.500

Страница 1: ... SPRAY BODY 1 Thread SPRAY HOSE 4 with SEAL WASHER 5 to SPRAY BODY 1 Connect other end of HOSE 4 with SEAL WASHER 6 to side outlet NIPPLE 7 of the TRANSFER VALVE 8 PUTTY 6 2 7 8 1 9 Tighten LOCKNUTS 1 with WRENCH 5 supplied to secure VALVE BODIES 3 3a Install LOCKNUT 1 and RUBBER WASHER 2 onto VALVE BODIES 3 3a From under side of mounting surface install VALVE BODY 3 3a through valve mounting hole...

Страница 2: ...gh drain outlet Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 2 must face towards the rear of the BIDET DRAIN OUTLET Install FOAM GASKET 3 and FLANGE 4 onto drain body from above BIDET and tighten FLANGE 4 firmly 1 4 3 4 Fig A Fig B Fig A Fig B 7 FLANGE GASKET Check DRAIN FLANGE in BIDET to ensure that WHITE FOAM GASKET 1 is fully compressed and not visible Fig A DRAIN FL...

Страница 3: ...r new POP UP DRAIN installation is now complete Fig C Note Tailpeice on pop up drain is 1 1 4 O D Fig C Fig B ATTACH CABLE CONNECTOR 8 Operate LIFT KNOB 1 to verify that STOPPER 2 opens and closes Note If STOPPER 2 does not open and close properly then refer to the troubleshooting section of these instructions CHECK OPERATION OF POP UP INSTALL DIVERTER KNOB 9 Fig C 1 1 4 O D M968795Rev 1 1 DOWN Fi...

Страница 4: ...2 3 4 5 3 2 1 1 2 Turn HANDLE STEM 1 to OFF position Place the ACRYLIC HANDLE 2 on the HANDLE STEM 1 Install the HANDLE SCREW 3 and tighten securely Push in INDEX BUTTON 4 Turn HANDLE STEM 1 to OFF position Place the HANDLE ADAPTER 2 on the HANDLE STEM 1 Install the ADAPTER SCREW 3 and tighten securely Position LEVER HANDLE 4 and place on ADAPTER 2 Install the HANDLE SCREW 5 and tighten securely w...

Страница 5: ...llow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode Fig B REMOVE CAM Fig E Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body w...

Страница 6: ... at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the Cam...