1

Champion4 Valve Replacement Instructions

Turn off and disconnect the 
supply  line.  Drain  the  tank 
by lifting tower. 

Sponge out any remain-ing
water.  Detach  the  hook 
from lift arm.

Disconnect  the  refill  tube 
from the  tower. Detach  the 
tank from bowl by removing 
tank fasteners. (not shown)

Place the tank on it’s side, 
remove 

the 

coupling 

gasket  (not  shown)  and 
lock nut.

Remove  the  old  flush 
tower and discard.

Install a  New  Champion4 
Flush  valve  with the  vent 
tube 

positioned 

as 

shown.

Tighten  the  lock  nut  hand 
tight  plus  an  additional  ¾
turn.

Align  the  lock  nut  “flat”
parallel  to  back  edge  of 
tank.

Remove 

inches 

(50mm) from the end of 
the  refill  tube;  save  the 
“S” clip  for  the  next 
step.

Re-insert  the  “S” clip 
into  the  end  of  the 
refill tube.

Affix  the  end  of  the 
refill  tube  to  the  valve 
overflow at the location 
shown.

Alternate  view  of  the 
refill tube attachment.

Remove the Hair Pin Cotter 
from  the  new  Clevis  Pin 
assembly.  Insert  the  clevis 
pin  through  the  inbound 
hole location.

Re-insert  the  hair  pin 
cotter  through  the  clevis 
pin hole.

Properly 

configured 

Champion4 

Flushing 

System.

Replace 

the 

coupling 

gasket  over  the  lock  nut, 
re-fit the  tank  assembly to 
the  bowl  and  tighten  the 
tank mounting fasteners in 
a  alternating  manner.  Re-
connect  the  water  supply. 
Adjust the water level to  1 
inch  below  the  overflow 
tube. Replace the tank lid.

ISPN 7301121-100A