Since the manufacturer has a policy of continuous product
and product data improvement, it reserves the right to
change design and specifications without notice.

© 2009 American Standard Heating & Air Conditioning

11-AC11D1-4

IMPORTANT — 

This Document is 

customer property

 and is to remain with this unit.  Please return to service information pack

upon completion of work.

These instructions do not cover all variations in systems
nor provide for every possible contingency to be met in
connection with installation.  All phases of this installa-
tion must comply with NATIONAL, STATE AND LOCAL
CODES. 

 Should further information be desired or should

particular problems arise which are not covered sufficiently for
the purchaser’s purposes, the matter should be referred to your
installing dealer or local distributor.

A. GENERAL

The following instructions cover 4A7A4 Condensing Units.

NOTICE: These outdoor units may be used with indoor units
equipped with Thermostatic Expansion Valve or Accutron™
Flow Control Check Valve (F.C.C.V.) assembly for refriger-
ant flow control only.

▲ 

WARNING:

  These units use R-410A refriger-

ant which operates at 50 to 70% higher pressures than R-22.
Use only R-410A approved service equipment. Refrigerant
cylinders are painted a “Rose” color to indicate the type of
refrigerant and may contain a “dip” tube to allow for charging
of liquid refrigerant into the system. All R-410A systems use
a POE oil that readily absorbs moisture from the atmosphere.
To limit this “hygroscopic” action, the system should remain
sealed whenever possible. Never break a vacuum with air
and always change the driers when opening the system for
component replacement.

Check for transportation damage after unit is uncrated.  Report
promptly, to the carrier, any damage found to the unit.

To determine the electrical power requirements of the unit, refer
to the nameplate of the unit.  The electrical power available must
agree with that listed on the nameplate.

B. LOCATION & PREPARATION OF THE UNIT

1. When removing unit from the pallet, notice the tabs on the
basepan. Remove tabs by cutting with a sharp tool as shown in
Figure 2 (see page 2).

2. The unit should be set on a level support pad at least as large
as the unit base pan, such as a concrete slab. If this is not the
application used please refer to application bulletin
“ALG-APG**-EN” (* denotes latest revision).

3. The support pad must NOT be in direct contact with any
structure.  Unit must be positioned a minimum of 12" from any
wall or surrounding shrubbery to insure adequate airflow.  Clear-

Condensing Units

Models:

   4A7A4

CAUTION

!

UNIT CONTAINS R-410A REFRIGERANT!

R-410A OPERATING PRESSURE EXCEEDS THE 
LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS 
REQUIRED. FAILURE TO USE PROPER SERVICE 
TOOLS MAY RESULT IN EQUIPMENT DAMAGE OR 
PERSONAL INJURY.

SERVICE

USE ONLY R-410A REFRIGERANT AND

APPROVED POE COMPRESSOR OIL.

INSTALLER'S GUIDE

ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

TOP DISCHARGE — UNRESTRICTED

5 FT. ABOVE UNIT

1

Содержание 4A7A4018C

Страница 1: ...msuse aPOEoilthatreadilyabsorbsmoisturefromtheatmosphere Tolimitthis hygroscopic action thesystemshouldremain sealed whenever possible Never break a vacuum with air and always change the driers when opening the system for component replacement Check for transportation damage after unit is uncrated Report promptly to the carrier any damage found to the unit To determine the electrical power require...

Страница 2: ...tach R 410A Caution Label located in documentation package to access panel of indoor section IMPORTANT The outdoor unit is shipped with the proper size orifice and a stick on orifice size label in an envelope attached to the outdoor unit Outdoor unit nameplate will have correct orifice size specified as BAYFCCV A for rated perfor mance D INSTALLING REFRIGERANT LINES CAUTION Ifusingexistingrefriger...

Страница 3: ...cover to access service valves 2 Before brazing remove plugs from external copper stub tubes Clean internal and external surfaces of stub tubes prior to brazing 3 Cut and fit tubing minimizing the use of sharp 90 bends 4 Insulate the entire gas line and its fittings 5 Do NOT allow uninsulated liquid line to come in direct contact with bare gas line 6 Precautions should be taken to avoid heat damag...

Страница 4: ...th local codes 2 Power supply must agree with equipment nameplate 3 Install a separate disconnect switch at the outdoor unit 4 Ground the outdoor unit per local code requirements 5 Provide flexible electrical conduit whenever vibration trans mission may create a noise problem within the structure 6 The use of color coded low voltage wire is recommended to simplify connections between the outdoor u...

Страница 5: ... grounding of equipment must comply with local codes 3 Low voltage wiring to be No 18 AWG minimum conductor 4 ODT B must be set lower than ODT A 5 If outdoor thermostats ODT are not used connect W1 to W2 and W3 PRINTED FROM B152903 P02 NOTE W2 present only on 2 stage thermostat and furnace PRINTED FROM B152907 P03 NOTE W2 present only on 2 stage thermostat and furnace LEGEND FACTORY WIRING FIELD W...

Страница 6: ... 3 4 829 32 5 8 756 29 3 4 5 8 5 16 143 5 5 8 92 3 5 8 210 8 1 4 79 3 1 8 508 20 4A7A4030B 3 1 832 32 3 4 829 32 5 8 756 29 3 4 3 4 5 16 143 5 5 8 92 3 5 8 210 8 1 4 79 3 1 8 508 20 4A7A4036B 3 1 933 36 3 4 829 32 5 8 756 29 3 4 3 4 3 8 143 5 5 8 92 3 5 8 210 8 1 4 79 3 1 8 508 20 4A7A4042B 4 1 943 37 1 8 946 37 1 4 870 34 1 4 3 4 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 508 20 4A7A4048B 4A7A4060C 4 ...

Страница 7: ...Pub No 11 AC11D1 4 PAGE 7 INSTALLER S GUIDE MOUNTING HOLE LOCATION NOTE ALL DIMENSIONS ARE IN MM INCHES NOTE For model base size see table on page 6 From Dwg D152637 Rev 2 ...

Страница 8: ...s with thermostat 11 Is correct speed tap being used Indoor blower motor 12 Operate complete system in each mode to insure safe operation INDOOR THERMOSTAT SWITCH SETTING 1 1 Fan Switch TO CHECK Off Cool Heat Auto On COMPONENT OPERATION Indoor Outdoor Compressor 3 Comp Furnace Blower Fan Runs Sump Heat Runs Runs Heater Comes On Step No CHECKOUT PROCEDURE WITH MAIN POWER DISCONNECTS CLOSED ON 1 Als...

Отзывы: