background image

Place back-up nuts on both bottom bolts, and
the top left-hand bolt only.

Adjust the two lower back-up nuts so that front
face of nuts is flush with finished wall.

Adjust waste horn to project 5/16" from
finished wall.

Using a level, adjust the top left back-up nut so that
it is in the same vertical plane as the lower left back-up
nut.  (If wall surface is irregular, the three back-up
nuts must be positioned to allow a minimum 1/16"
gap between fixture and wall surface.)

NOTE:

  Bearing nuts and washers must be set

to take full loading from the fixture allowing
1/16" clearance between fixture and wall.

Follow support manufacturer's recommended
setting of closet outlet connection.

Place felt or neoprene gasket (wax ring not
recommended) on closet outlet.

When the fixture is installed, closet outlet
gasket must be compressed sufficiently to
assure a gas and watertight seal.

Install bowl on support using cap nuts and fiber
washers with the back-up nuts and washers.

DO NOT APPLY TOP RIGHT FIBER WASHER
AND CAP NUT UNTIL OTHER CAP NUTS
HAVE BEEN FIRMLY TIGHTENED USING A
WRENCH.

Install top right cap nut with fiber washer and
run up hand tight.  Wrench tighten approximately
1/4 turn.

Apply sealant to gap between bowl and finished
wall.  Remove excess sealant.

S

A

V

E

 

F

O

R

 

F

U

T

U

R

E

 

U

S

E

1

730480-100 Rev B

730480-100 Rev B

730480-100 Rev B

730480-100 Rev B

Saniwares

P r o d u c t   n a m e s   l i s t e d   h e r e i n   a r e   t r a d e m a r k s   o f   A m e r i c a n   S t a n d a r d   I n c .
©   A m e r i c a n   S t a n d a r d   I n c .   2 0 0 6

SPONGE

WASHER

TANK MTG.

BOLTS

SANITARY

BAR

NUT

WASHER

3

5

6

2

4

Refer to instructions supplied with 
wall carrier for proper installation 
of 4-bolt support system wall 
cavity requirements and rough-in 
information for waste outlet piping.

!

- 2 -

7

8

ADJUSTMENTS

The flushometer tank is designed and factory-adjusted to provide a consistent, 
safe seal depth in the bowl after each flush.  Field refill adjustment is not required.  
The refill has been preset and locked.

  

FLUSH ACTUATOR ADJUSTMENT

 - The spacing between the bellcrank and 

flush actuator may be adjusted to assure positive operation of the trip lever.    
   
   Proceed as follows:

   Remove tank cover and check that there is approximately 1/32" (0.8mm) gap  
   between the top of the actuator and bottom of the spring rod when it is lifted to  
   remove slack from linkage.

   If necessary, loosen set screw in actuator cap and turn cap to increase gap 
   (clockwise) or decrease gap (counterclockwise), as needed.

 
   Tighten setscrew securely after adjustment is completed.  Replace tank cover.

CARE AND CLEANING 

When cleaning your toilet, wash it with mild, soapy water, rinse thoroughly with clear water and dry with a soft cloth.  
Avoid detergents, disinfectants, or cleaning products in aerosol cans.  NEVER use abrasive scouring powders or 
abrasive pads on your toilet seat.  Some bathroom chemicals and cosmetics may damage the seat's finish.

REPAIR PARTS LIST

NOTE: "XXX" and "YYY" represent color or trim finish options.

          Specify when ordering.

ITEM

PART NO.

DESCRIPTION

QTY

1

2

3
4
5

6
7
8
9

10

1

1

1
1
1

1
1
1
1
1

1
1

738473-YYY0A
738494-YYY0A
4098.100.XXX

4098.800.XXX

735083-400.XXX
3402.016.XXX
738493-0070A
738495-0070A
730599-0070A
738496-0070A
047562-0070A
047563-0070A
730292-0070A

735083-600.XXX
603111-0030A

TRIP LEVER-LH
TRIP LEVER-RH
TANK (COMPLETE WITH COUPLING
COMPONENTS AND L.H. TANK TRIM)
TANK (COMPLETE WITH COUPLING
COMPONENTS AND R.H. TANK TRIM)
TANK COVER
BOWL
SPRING ROD ASSEMBLY-LH
SPRING ROD ASSEMBLY-RH
COUPLING GASKET
LOWER SUPPLY ASSEMBLY (35 PSI)
UPPER SUPPLY ASSEMBLY
VALVE CARTRIDGE ASSEMBLY
TANK COUPLING KIT

TANK COVER FOR LOCKING DEVICE
COVER LOCKING DEVICE KIT

TANK

COUPLING NUT

FLEXIBLE
SUPPLY

WATER INLET

COMPRESSION
COLLAR

WASHER

VALVE NUT

TRIM PLATE

VALVE

1

2

3

5

8

9

7

 6 

 10

- 3 -

SET

SCREW

1/32"
APPROX.

AMERICAN-STANDARD ONE-YEAR LIMITED WARRANTY

If inspection of this American-Standard plumbing product, within one year after its initial installation, confirms that it is defective in materials or 

workmanship, American-Standard will repair or, at its option, exchange the product for a similar model. 

This warranty

 does not apply

 to local building code compliance.  Since local building codes vary considerably, the purchaser of this product should check 

with a local building or plumbing contractor to insure local code compliance before installation.

This warranty 

shall be void

 if the product has been moved from its initial place of installation; if it has been subjected to faulty maintenance, abuse, 

misuse, accident or other damage; if it was not installed in accordance with American-Standard's instructions; or if it has been modified in a manner 
inconsistent with the product as shipped by American-Standard.

American-Standard's option to repair or exchange the product under this warranty does not cover any labor or other costs of removal or installation, 

nor 

shall American-Standard be responsible for any other incidental or consequential damages attributable to a product defect or to the repair or 
exchange of a defective product, all of which are expressly excluded from this warranty.

 (Some states or provinces do not allow the exclusion or 

limitation of implied warranties, so this exclusion may not apply to you.)

This warranty gives you specific legal rights. You may have other statutory rights that vary from state to state or from province to province, in which case 

this warranty does not affect such statutory rights.
For service under this warranty, it is suggested that a claim be made through the contractor or dealer from or through whom the product was purchased, or 
that a service request (including a description of the product  model and of the defect) be sent  to the following address:

- 4 -

TROUBLESHOOTING GUIDE

NOTE:

   The presence of a small amount of water in the bottom of the tank is normal. The air inducer is designed to leak 

for short periods during each flush cycle as a self-cleaning action.  Drippage is drained into the bowl. If used on water 

system containing excessive sand and/or debris, a periodic cleanup of inlet strainer is recommended. (See enclosed    

    instructions for strainer cleaning.) 

!

     WARNING

When servicing  or replacing components of the flushometer tank system, be sure that the

water supply is shut off and the toilet is flushed to relieve pressure in the flushometer tank.

For service of the Flushometer Tank System, see enclosed literature.

 

    PROBLEM                 POSSIBLE CAUSE                                                  CORRECTIVE ACTION

 Does not flush 

a.    Water supply valve closed. 

a.   Open valve and allow water to fill tank.

 

b.    Flush actuator incorrectly set. 

b.   Follow instruction to adjust flush actuator.

 

c.    Supply line blocked. 

c.   Shut off water supply, disconnect supply line, and inspect

 

 

 

 

all gaskets and washers.  Reassemble.

 

d.  Trip lever linkage damaged. 

d.   Check trip lever, linkage, and spring rod assemblies

 

 

 

 

for damage.

Poor or sluggish 

a.   Supply valve partly closed. 

a.   Open supply valve fully.  Be sure that proper supply tube

flush 

 

      

 

size is used.

 

b.  Plugged inlet strainer. 

b.  Remove and clean strainer per enclosed instructions

 

c.    Supply pressure too low. 

c.   Normal supply pressure must be at least 25 psi.

 

d.    Partially clogged trapway and/or 

d.   Remove obstruction.  Consult a plumber if necessary.

 

       drain pipe and/or vent.

 

e.    Malfunctioning pressure regulator. 

e.   Replace lower supply assembly.

Toilet leaks 

a.    Poor supply line connection. 

a.   Review Step 7 of installation procedure.

 

b.    Poor bowl to wall waste outlet  

b.   Review Step 3 through 5 of installation procedure.

 

 

connection.

 

c.  Tank/bowl connection. 

c.  Check tank for movement.  Refer to Step 6.

Toilet does not 

a.    Supply pressure too low. 

a.   Normal supply pressure must be at least 25 psi.

shut off 

b.    Flush actuator incorrectly set. 

b.   Follow instructions to adjust flush actuator.

In the United States:

American Standard Inc.,

P.O. Box 6820

Piscataway, New Jersey 08855

Attention: Director of  Consumer Affairs

For residents of the United States,

warranty information may also be

obtained by calling the following

toll free number: (800) 442-1902

www.americanstandard-us.com

In Canada:

American-Standard, 

2480 Stanfield Road

Mississauga, Ontario 

Canada L4Y 1S2

Toll Free:  (800) 387-0369

www.americanstandard.ca

In Mexico:

Customer Service Manager         

Ideal Standard, S.A. de C.V.

Via Morelos #330

Col. Santa Clara

Ecatepec 55540 Edo. Mexico

www.americanstandard.com.mx

Closet Carrier Support
Putty Knife
Regular Screwdriver
Adjustable Wrench
Sealant
Tape Measure
Flexible Supply Tube
Carpenters Level

RECOMMENDED TOOLS

AND MATERIALS

Model 2093 Elongated

GLENWALL 1.6 GPF TWO-PIECE
PRESSURE-ASSISTED

WALL-MOUNTED TOILETS

INSTALLATION INSTRUCTIONS

Thank you  for selecting American Standard - the benchmark of fine quality for over 100 years.  To ensure this
product is installed properly, please read these instructions carefully before you begin. (Certain installations may 
require professional help.) Also be sure your installation conforms to local codes.

CAUTION:  PRODUCT IS FRAGILE.  TWO PEOPLE ARE RECOMMENDED FOR
HANDLING TO AVOID BREAKAGE AND POSSIBLE INJURY!

NOTE:  

For proper operation product requires a minimum of 25 psi working line pressure

30

(762mm)

OR

32

(813mm)

14-3/4

(375mm)

9

(229mm)

29-1/2

(749mm)

7-1/2

(191mm)

191mm

(7-1/2)

14-1/2

(368mm)

OR

16-1/2

(419mm)

C/L OF WASTE

OUTLET

(4) 7/8

(22mm) DIA. HOLES

SUPPLY AS

REQUIRED

*

5/8

(16mm)

3-1/4

(83mm)

1-1/2

(38mm)

5-1/4

(133mm)

3-7/8

(98mm)

FINISHED WALL

FIN.

 FLOOR

3-1/4

(83mm)

3/4 (19mm)

REF.

6

(152mm)

8-1/2

(216mm)

4-1/8

(105mm)

OR

6-1/8

(156mm)

19-1/2

(495mm)

C/L

FINISHED WALL

CLOSET
CARRIER
SYSTEM

(3) NUTS

WASTE
HORN

5/16

LEVEL

FINISHED WALL

FIXTURE MOUNTING

Fixture studs should project
2-1/8" from face of finished wall.

Front View

Side View

FINISHED WALL

2-1/8"

(4) STUDS

1/16" (IRREGULAR
WALL SURFACE)

Install large rubber gasket over threaded outlet on
bottom of tank with tapered side out and lower tank onto
bowl so that the tapered end of gasket fits evenly into
bowl water inlet opening, and tank mounting bolts go
through mounting holes. Secure with metal washers
and nuts.

With tank parallel to wall, alternately tighten nuts until 
tank is snugged down evenly against sanitary bar on
bowl.

Install toilet seat according to manufacturer's directions.

CAUTION: 

DO NOT OVERTIGHTEN

NUTS MORE THAN REQUIRED

FOR A SNUG FIT!

INSTALL TANK AND TOILET SEAT

The following steps require a helper:

Connect water supply line between 
shutoff valve and tank water inlet 
fitting. Tighten coupling nuts 
securely. 

Turn on supply valve and allow
flushometer tank to fill.

Check for leakage at fittings,
tighten or correct as needed.

CONNECT WATER SUPPLY

Meets the American Disabilities Act Guidelines and ANSI A117.1

Requirements for the Physically Challenged

When installed, top of seat is

17" to 19" (432mm to 483mm)

from the finished floor.

!

Отзывы: