Rev. 5
77
Operation
Example Setup
The Current Limit accessible in the Load submenu should be set to the
rated current to prevent accidental operation of the magnet above rated
field/current. The magnet specification sheet also indicates whether a
persistent switch is installed and provides the recommended heating
current. The persistent switch information is entered in the Load
submenu.
EXCELLENCE IN MAGNETICS AND CRYOGENICS
American Magnetics, Inc.
P.O. Box 2509, 112 Flint Road, Oak Ridge, TN 37831-2509
Phone: (865) 482-1056
Fax: (865) 482-5472
Internet: http://www.americanmagnetics.com E-mail: [email protected]
0$*1(763(&,),&$7,216
AMI JOB #
MAGNET #
TYPE:
6ROHQRLG
MODEL:
&XVWRP
FOR:
$ : &U\R(QJLQHHULQJ/WG
DATE:
0D\
Rated Central Field @ 4.2K
1
---------------------------------
N*
Rated Current ------------------------------------------
DPSV
Max. Field Tested ------------------------------------------
N*
Field to Current Ratio -----------------------------
JDXVVDPS
Homogeneity over a 1 cm DSV --------------------------------
Measured Inductance -----------------------------------
KHQU\V
Charging Voltage ---------------------------------------
YROWV
Axial Clear Bore --------------------------------------
LQFKHV
Overall Length (flange to flange) --------------------
LQFKHV
Maximum Outside Diameter ------------------------------
LQFKHV
Weight ---------------------------------------------------
OEV
Recommended Persistent Switch Heater Current ---------------
P$
Persistent Switch Heater Nominal Resistance
2
------------
RKPV
Magnet Resistance in Parallel with Switch
2
--------------
RKPV
Mounting:
KROHVWDSSHGIRU0;RQWRSIODQJHHTXDOO\VSDFHG
RQDLQFKEROWFLUFOHGLDPHWHU
1.
Magnet not warranted for operation above 80 kG.
2.
All resistance measurements made at room temperature.
Figure 3-13.
Example Magnet Specification Sheet.
Содержание 05100PS-430-601
Страница 2: ......
Страница 10: ...x Rev 5 List of Figures ...
Страница 12: ...xii Rev 5 List of Tables ...
Страница 18: ...xviii Rev 5 Foreword Safety Summary ...
Страница 30: ...12 Rev 5 Introduction Operating Characteristics ...
Страница 42: ...24 Rev 3 Installation Power Up Procedure ...
Страница 114: ...96 Rev 5 Operation Summary of Operational Limits ...
Страница 119: ...Rev 5 101 Remote Interface Reference SCPI Command Summary LOCK ABsorber LOCK BRIGHTness LOCK NETsetup ...
Страница 156: ...138 Rev 5 Remote Interface Reference Error Messages ...
Страница 168: ...150 Rev 5 Service Return Authorization ...
Страница 190: ...172 Rev 5 Appendix Power Supply Details Figure A 3 Model 08150PS Dimensions Top and Side Views ...
Страница 220: ...202 Rev 5 Appendix Persistent Switch Operation Flowchart Figure A 17 Persistent Switch Operation Flowchart Page 3 ...
Страница 226: ...208 Rev 5 Index ...