Operation
Default Display : Voltage
Programmer display. The parameter displayed (field or current) is toggled
by pressing
SHIFT
followed by
FIELD <> CURRENT
. Thus, if field strength
is being displayed, pressing
SHIFT
followed by
FIELD <> CURRENT
will
cause the current to be displayed; conversely, if current is being displayed,
pressing
SHIFT
followed by
FIELD <> CURRENT
will cause the field
strength to be displayed. Operating current is always displayed in
amperes (A). Operating field strength may be displayed in kilogauss (kG)
or tesla (T) if a coil constant has been specified in the setup
1
. If field
strength is being displayed, the units (kG or T) in which it is displayed can
be toggled by pressing
SHIFT
followed by
FIELD UNITS
.
Note
Note that the displayed field strength is not directly measured, but
rather is calculated by multiplying the coil constant entered in the
setup menu by the measured current flow of the Model 430 power
supply system.
3.2.2 Voltage
Display
The voltage display indicates either the voltage across the magnet (Vm) or
the power supply output voltage (Vs). This is always displayed in the lower
left corner of the display (see Figure 3-1), regardless of what else is being
displayed on the Model 430 Programmer display. The parameter displayed
(magnet voltage or power supply voltage) is toggled by pressing
SHIFT
followed by
Vs <> Vm
. Vm indicates the voltage measured across the
terminals of the connected superconducting magnet. In order for the Model
430 Programmer to measure the magnet voltage, the magnet voltage taps
must be connected to the Model 430. Normally this is done through the
Magnet Station Cable provided by AMI (if the whole magnet system is
provided by AMI). Vs indicates the Model 430 Programmer-controlled
power supply output voltage.
Note
Note that the displayed power supply voltage (Vs) is not directly
measured, but rather is calculated based on power supply control
voltage being provided by the Model 430 Programmer and the power
supply input control voltage and output voltage values entered in
the setup menu.
1. Refer to section 3.10.2.2 on page 54.
Содержание 05100PS-430-601
Страница 2: ......
Страница 10: ...x Rev 5 List of Figures ...
Страница 12: ...xii Rev 5 List of Tables ...
Страница 18: ...xviii Rev 5 Foreword Safety Summary ...
Страница 30: ...12 Rev 5 Introduction Operating Characteristics ...
Страница 42: ...24 Rev 3 Installation Power Up Procedure ...
Страница 114: ...96 Rev 5 Operation Summary of Operational Limits ...
Страница 119: ...Rev 5 101 Remote Interface Reference SCPI Command Summary LOCK ABsorber LOCK BRIGHTness LOCK NETsetup ...
Страница 156: ...138 Rev 5 Remote Interface Reference Error Messages ...
Страница 168: ...150 Rev 5 Service Return Authorization ...
Страница 190: ...172 Rev 5 Appendix Power Supply Details Figure A 3 Model 08150PS Dimensions Top and Side Views ...
Страница 220: ...202 Rev 5 Appendix Persistent Switch Operation Flowchart Figure A 17 Persistent Switch Operation Flowchart Page 3 ...
Страница 226: ...208 Rev 5 Index ...