The Production Cycle Timer
Owners Manual
1.4.7 Selecting the PCT Timing Mode
The PCT can be configured to time in tenths of seconds, seconds, tenths of minutes, minutes, tenths of hours, or
hours. The timing mode is selected by three switches on SW2.
SW2.8
SW2.7
SW2.6
Timing Mode
OFF
OFF
OFF
XXX.X Seconds
OFF
OFF
ON
XXXX Seconds
OFF
ON
OFF
XXX.X Minutes
OFF
ON
ON
XXXX Minutes
ON
OFF
OFF
XXX.X Hours
ON
OFF
ON
XXXX Minutes
Page 11
Shown with switches
1, 7, and 8 ON