Страница 3: ...osoft NET Framework 8 Installing Bullhorn Tools 8 Bullhorn Information Line 11 Contacting Technical Services 11 CHAPTER 2 Installation 12 RM4150 RM4151 Overview 12 Preparing for the Installation 15 El...
Страница 4: ...t Off 45 Readings Graphics 47 Configure Digital and Accumulator Inputs 48 Edit Power Information 51 Change SIM Destination 52 Work with Templates 52 Export or Delete Templates 53 Upgrade Firmware 54 E...
Страница 5: ...RM4100 Series User Guide Contents v Appendix F Glossary 67 Index 71...
Страница 6: ...nformation included in the current release of this manual Bullhorn Tools 1 6 Bullhorn Tools configuration software was updated to include RM4100 Series units including the RM4150 and RM4151 For more i...
Страница 7: ...tting Started Chapter 2 Installation Chapter 3 Configuration NOTE The RM4100 Series User Guide and other related documentation can be downloaded in Adobe PDF format from Bullhorn Web under the Help me...
Страница 8: ...tricity from yourself and your clothing by touching a grounded metal object before handling electronic equipment Table 1 1 Safety and Equipment Symbols Symbol Description Caution Failure to observe th...
Страница 9: ...protection rectifier interface and test point filtering functionality The RM4150 and RM4151 measure the output of rectifier current across shunt resistors Additionally the RM4150 and RM4151 support G...
Страница 10: ...aled lead acid battery If you need to replace the battery please contact Technical Support for information about purchasing a replacement battery American Innovations part number 370109 000 manufactur...
Страница 11: ...connection is required The RM4100 Series units require grounding Antenna Installation The dual GSM GPS antenna should be placed outside the rectifier Mounting the Enclosure Place the RM4150 or RM4151...
Страница 12: ...r preparing the mounting surface for installation such as a hand drill and metal masonry or wood drilling bit Installation drawing provided Required Hardware Software IBM compatible computer with the...
Страница 13: ...cations with Bullhorn Web Using the Bullhorn Tools software requires that your computer be installed with Microsoft NET Framework version 4 0 or higher IMPORTANT Before installing Bullhorn Tools first...
Страница 14: ...ion and to create settings templates which can be used to configure multiple similar units NOTE Before installing an upgrade to Bullhorn Tools first uninstall the previous version Bullhorn Tools requi...
Страница 15: ...ow click Next 5 On the End User License Agreement window click the I accept the terms in the License Agreement check box and then Next Figure 1 2 End User License Agreement 6 In the Custom Setup windo...
Страница 16: ...horn Tools window click Install Figure 1 4 Ready to Install Bullhorn Tools 8 When the installation is complete click Finish Figure 1 5 Installation Complete 9 To start Bullhorn Tools click the Bullhor...
Страница 17: ...s the packet log when prompted 3 Use your telephone keypad to enter the unit serial number when prompted The unit serial number is included on the bar code label on the side of the unit It is also inc...
Страница 18: ...G CH 5 channels 1 through 5 are isolated inputs that support analog 150 V DC 150 V AC 4 20 mA with external resistor or active digital input devices Input DIGITAL CH 1 and DIGITAL CH 2 are non isolate...
Страница 19: ...RM4100 Series User Guide Installation 13 Figure 2 1 RM4150 and RM4151 Unit Hardware Configuration...
Страница 20: ...RM4150 and RM4151 Figure 2 2 RM4150 RM4151 Enclosure Connectors Antenna and USB Config Figure 2 3 RM4150 RM4151 Enclosure Connectors Power and Ground NOTE Because of the variations in customer s insta...
Страница 21: ...n page 7 for more information Electrostatic Discharge Electrostatic Discharge ESD can damage electronic components Provide ESD protection by wearing an anti static wrist strap attached to any unpainte...
Страница 22: ...hould be available to place the unit to the back or front of the rectifier case so that it is not directly over the air vent Enough room will also be needed for input wires that will be routed from th...
Страница 23: ...ent install and connect a mercury or solid state relay to the unit page 22 8 Connect inputs to RM4150 or RM4151 input channels page 23 9 Configure RM4150 or RM4151 for service using Bullhorn Tools sof...
Страница 24: ...it Complete the following steps to mount the RM4150 or RM4151 using the four 4 magnetic disks screws and nuts from the accessory kit 1 Thread a screw through each magnetic disk 2 Attach a disk to each...
Страница 25: ...f the RM4150 or RM4151 enclosure labeled GPS ANTENNA see Figure 2 2 on page 14 for location of the connector The cable for the GPS antenna is labeled It also has a red ring at the top of the connector...
Страница 26: ...s supply simultaneously Equipment intended for permanent connection to the mains shall have provisions for connection of a wiring system in accordance with ANSI NFPA 70 NEC with CSA C22 1 CEC Part I o...
Страница 27: ...location of the ground connection on the unit 1 Connect ground wire attached to the unit to rectifier frame using spade connectors Figure 2 9 Ground Wire with Spade Connectors 2 If necessary use I be...
Страница 28: ...he relay on a suitable surface If you are installing the mercury relay the relay functions with a contact in a pool of mercury therefore making orientation of the relay important Ensure that the relay...
Страница 29: ...en 5308UE or equivalent for wiring inputs 1 Connect your rectifier input wires to the RM4150 DIGITAL CH 1 and DIGITAL CH 2 and ANALOG CH 1 through ANALOG CH 5 in Figure 2 11 or to the RM4151 DIGITAL C...
Страница 30: ...rectifier is turned off turn ON to restore power to field wiring 5 Continue with Chapter 3 Configuration on page 25 to configure the RM4150 for service 6 After configuring the RM4150 or RM4151 a Remo...
Страница 31: ...Synchronization Software 2 Connect the Unit and Start Bullhorn Tools 3 Configure Unit including sending a test message applying a template setting the unit clock creating a transmission schedule sett...
Страница 32: ...uration cable in the USB port of your computer Connect the other end of the cable in the USB CONFIG port on the unit 2 Power on the unit 3 Double click the Bullhorn Tools program icon on the desktop o...
Страница 33: ...Unit Overview window displays Click Refresh to update unit settings Figure 3 2 Unit Overview Window NOTE The column to the right of Unit Information displays channel readings in a graphical format an...
Страница 34: ...and battery data The window also includes visual representations gauges and buttons of current readings for all enabled channels Send Test Message send a test message from the unit to verify communic...
Страница 35: ...g must be updated if the SIM card has been replaced in the unit Work with Templates unit settings can be saved to a template to save time when configuring multiple identical units Saved templates can...
Страница 36: ...tion 1 Click the name of the unit in the navigation pane to view Unit Information Transmission Information Interrupter Information GPS Information and Power Information panes as well as the gauges for...
Страница 37: ...t either Profile or Test from the Select Command field Both Profile and Test command will send the current values of the data points Figure 3 6 Send Message Select Command 3 Click Send A packet is sen...
Страница 38: ...rent unit For information on how to export or delete a saved template refer to Work with Templates Complete the following steps to import a saved template optional and then apply a template to the uni...
Страница 39: ...ck File Load Template 6 In the Apply Template window select a saved template from the Select template list Figure 3 9 Apply Template The settings used with the template display Figure 3 10 Template Se...
Страница 40: ...e You can also click the up and down arrows to adjust the time For more information about UTC visit the Naval Oceanography Portal website at http aa usno navy mil faq docs UT php 3 Select either On or...
Страница 41: ...porting Mode enter a value in the Day of Month 1 field You can also click the up and down arrows to adjust the value Repeat as needed for Day of Month 2 Day of Month 3 and Day of Month 4 fields Figure...
Страница 42: ...ily and Start Stop require additional settings a If you selected Daily interrupter mode enter a Start Time and a Stop Time i Enter a time in the text field For example typing a 2 will display 2 00 AM...
Страница 43: ...the number of seconds in the Off Time field to specify the amount of time current is switched off You can also click the up or down arrow to increase or decrease the number of seconds 4 Set Output Syn...
Страница 44: ...or one of the Enabled values for each channel as needed The following lists the definition for each of the Enabled values DC Enabled CH1 CH5 input is DC Instant Off CH3 measures reading at Instant Of...
Страница 45: ...CH1 and CH2 Refer to Technical Specifications for channel ratings 1 Click Digitals Accumulators The Digitals Accumulators window displays Figure 3 15 Digital Enable Disable 2 Select either Enabled or...
Страница 46: ...and alarm settings for each analog channel that you enabled shown under Readings Refer to Glossary for definitions of fields and terms Readings can be configured in one of the following modes DC or AC...
Страница 47: ...C or AC 1 Click the next to the channel name such as Channel 1 to expand if not already expanded Figure 3 16 Channel 1 with Reading Gauge NOTE The Channel window includes a graphic representation a ga...
Страница 48: ...nalog CH3 DC The input and alarm settings window displays Figure 3 17 Channel Input and Alarm Settings 3 Select either Volts or Milli Volts from the Input Type drop down list 4 Enter the maximum volta...
Страница 49: ...change the value 8 Enter the minimum scaled value in Scaled Minimum Value field You can also use the up and down arrows to change the value NOTE The Scaled Maximum Value must be greater than the Scale...
Страница 50: ...he analog channel dial icon shown in the setup window as well as on the Unit Overview window The yellow and orange sections of the dial mark the deadband value 2 00 that was entered in the Low Alarm D...
Страница 51: ...9 Instant Off and Input Settings 3 Enter a value in milliseconds in the IOX Edge Offset field to set how long the unit will wait before taking a measurement after power from the rectifier has been tur...
Страница 52: ...window as well as the Unit Overview window under the gauge for DC enabled channels only The value will also be used with Scaled Maximum Value and Scaled Minimum Value 8 Enter the maximum scaled value...
Страница 53: ...t Instant Off on the Unit Overview window The graphic includes a gauge that shows the Scaled Maximum Value along with the Low Alarm Deadband and High Alarm Deadband see also Figure 3 18 as well as the...
Страница 54: ...ings Accumulator Settings window displays Figure 3 21 Digital Settings Accumulator Settings 3 Enter a value in milliseconds in Input Persistence field You can also use the up and down arrows to change...
Страница 55: ...dge select either Reset on Falling Edge or Reset on Rising Edge from the Alt Channel Edge drop down list Figure 3 22 Reset on Alt Channel Edge ii For Reset on Count enter a value in Reset At the value...
Страница 56: ...settings or Cancel to clear all fields The Unit Overview window will display a graphic for the digital channels that you enabled Yellow indicates a High input state gray indicates a Low input state Th...
Страница 57: ...Click Power The Power window displays Figure 3 25 Power Settings 2 Click the down arrow in Install Date field to open a calendar Figure 3 26 Battery Installation Calendar 3 Select a date To clear the...
Страница 58: ...for the new SIM card Table 3 1 SIM Card Types and Destinations 1 Click Action Change SIM 2 Select a type in SIM Destination field Figure 3 27 SIM Destination 3 Click Save to save change or Cancel to...
Страница 59: ...saved template refer to Apply a Template Complete the following steps to export or delete a template 1 Click File Template Management Figure 3 29 Template Management 2 To export a saved template to yo...
Страница 60: ...pgrade Firmware 2 Click Browse to search for the firmware file This file should have the extension bhf a Open the firmware file b Click Upgrade When the firmware has been updated the Firmware Version...
Страница 61: ...on 55 Exit Bullhorn Tools Complete the following steps 1 Click File Exit 2 Disconnect the configuration cable from the unit and your computer 3 Re enable any synchronization software previously disabl...
Страница 62: ...C DC Input Voltage 10 14 V DC Current 1 5 A DC max AC Input requires optional external AC DC power supply Voltage 100 240 V AC Current 0 15 0 3 A AC Frequency range 50 60 Hz Battery Power Sonic PS 120...
Страница 63: ...s User Guide Technical Specifications 57 Scan Rate accumulator input sampled 20 times per second with a minimum pulse width of 250 ms Interconnect cable Belden 5308UE 300 Vrms rated FT4 600 V 105 C or...
Страница 64: ...acement or fuse replacement procedures Replacing the Battery Complete the following steps WARNING To prevent electrostatic discharge ESD damage when handling electronic equipment always wear an anti s...
Страница 65: ...RM4100 Series User Guide Battery Replacement 59 Figure B 1 RM4150 Faceplate 5 Set aside cover 6 Disconnect the battery highlighted in yellow...
Страница 66: ...ift battery from unit 8 Replace with new battery 9 Connect new battery 10 Replace unit cover 11 Tighten cover corner screws 12 Reconnect input channel wiring 13 Turn power ON to restore power to field...
Страница 67: ...le item in the RM4150 RM4151 is the battery Sealed Lead Acid Battery Use Bullhorn Tools software or a voltmeter to monitor the battery voltage level The battery is considered low at 11 0 volts and dea...
Страница 68: ...fy the RSSI level is sufficient for transmissions see View Unit Information Based on the unit type verify the RSSI meets the following qualifications GSM Digital Cellular unit requires an RSSI greater...
Страница 69: ...he application Durakool information can be found on the AEC web page at the following address http www aecsensors com html In the Durakool documentation the following two situations are explained that...
Страница 70: ...supplied that we supply to enable the tracking of the shipment date The approximate age of the relay may be used to assist AI in return material response failure analysis and warranty claims Manufactu...
Страница 71: ...with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause h...
Страница 72: ...rements for UL 61010 1 2004 and CAN CSA C22 2 61010 1 2004 The RM4100 Series is also CE certified The TUV test mark assigned to the RM4100 Series as well as the CE symbol are shown below Export Contro...
Страница 73: ...nd applies hysteresis to low and high alarm values It is an area of equal value above and below the alarm values The deadband acts as a buffer when the input voltage passes below the deadband area thi...
Страница 74: ...mplete while in a particular state before that state is recognized as an alarm Persistence is an optional filter The purpose of the filter is to prevent short spurious noise pulses from triggering an...
Страница 75: ...scale Numbers closer to zero indicate a stronger signal Serial Unique serial number assigned to the unit at the factory for identification purposes Found on the Bullhorn Tools Unit Overview window SI...
Страница 76: ...locks and time Time zones around the world are expressed as positive or negative offsets from the UTC in eastward order from the western most zone UTC 12 00 For example Pacific Time Zone is UTC 08 00...
Страница 77: ...on 17 Input Persistence 48 Instant Off 45 Output Synchronization 37 Output Mode 37 Readings 38 starting 26 Sync Mode 37 unit information 30 Bullhorn Web 1 3 25 Documents 1 Downloads 7 Help site 1 C ca...
Страница 78: ...t 4 external overcurrent protection device 4 overcurrent protection device 4 power supply AC DC 20 installation 20 safety specifications 20 R Radio LED 13 read unit settings 27 rectifier current inter...
Страница 79: ...1 off supply 2 on supply 2 safety 1 Sync Mode 37 T technical support 11 template applying 32 exporting or deleting 53 transmission schedule 68 two way communication 12 U Unit Clock Time 69 USB 69 USB...