American Harvest 6033 Скачать руководство пользователя страница 1

USSC

1

851536

CORN & PELLET MULTIFUEL STOVE

6033

OWNER’S MANUAL

Installation - Operation - Maintenance Instructions - Repair Parts

READ THIS ENTIRE MANUAL

, THOROUGHLY, BEFORE ATTEMPTING THE INSTALL AND/OR

BURN YOUR NEW AMERICAN HARVEST CORN AND PELLET MULTI-FUEL STOVE. FAILURE TO

FOLLOW THESE INSTRUCTIONS MAY RESULT IN 

PROPERTY DAMAGE, BODILY INJURIES

OR EVEN DEATH

.

SAVE THESE INSTRUCTIONS

UNITED STATES STOVE COMPANY GRANTS NO WARRANTY, IMPLIED OR STATED,

FOR THE INSTALLATION OR MAINTENANCE OF THE STOVE AND ASSUMES NO

RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S).

UNITED STATES STOVE COMPANY - 227 INDUSTRIAL PARK ROAD-SOUTH PITTSBURG, TN. 37380

TECHNICAL ASSISTANCE (423) 837-2100 - (423) 837-2109 FAX

Safety Notice:

  If this stove is not properly installed, a 

house fire may result

.

For your safety, follow the installation directions. Contact local building or fire officials

about restrictions and installation requirements peculiar to your area.  

Do Not Plug

this appliance into an electrical outlet before reading and understanding all operations

and 

always unplug

 the unit before attempting any work or maintenance.  Do not

connect this stove to any chimney flue already serving another appliance.  Carefully

observe and maintain all 

clearances and combustibles.

A note about fuel:  

Use only 

dried shelled corn

 with a moisture content of 14%

or less 

(11 to 12% provides the best results);

 any pellet fuel used should have

an ash content of 1% or less.  If not efficiency will suffer, and your warranty may be

voided.

Your American Harvest Corn/Pellet Stove operates on a negative pressure.  Therefore,

all venting connections (elbows, T-pipe) must be sealed and airtight.

Keeping

Keeping

Keeping

Keeping

Keeping

North America

North America

North America

North America

North America

Warm Since

Warm Since

Warm Since

Warm Since

Warm Since

1869

1869

1869

1869

1869

Содержание 6033

Страница 1: ...ons Contact local building or fire officials about restrictions and installation requirements peculiar to your area Do Not Plug this appliance into an electrical outlet before reading and understandin...

Страница 2: ...You ve purchased one of America s Finest Multifuel Burning Stoves By heating with fuels such as corn and pellets you re helping CONSERVE AMERICA S ENERGY CONGRATULATIONS Heat Output 50 000 BTU HR Fuel...

Страница 3: ...nstalling the product The American Harvest stove is designed to burn shelled corn cherry pits or pelletized fuel such as wood pellets The burning of other solid fuels such as cord wood in this stove i...

Страница 4: ...urce will help achieve a more consistent burn DONOTUSECORNWITHAHIGHWAXCONTENT WOOD PELLETS As with corn be consistent in your pellet supplier Pellets will vary in content and burn characteristics from...

Страница 5: ...es to side and back wall combustible materials NOTE These are minimum clearances to combustible walls established by the testing lab The amount of room needed on the left side of the unit to access th...

Страница 6: ...nlet elevation It is recommended that at least 5 ft of vertical pipe be installed when the appliance is vented directly through a wall This will create some natural draft to prevent the possibility of...

Страница 7: ...o be airtight When venting into an existing masonry or factory built chimney the chimney must be cleaned with all creosote re moved The chimney must be a type suited for solid fuel WARNING The chimney...

Страница 8: ...e outside it MUST be terminated with a vertical 90 degree bend down or with a wind hood Failure to do so could result in a burn back during high winds blowing directly up the air inlet during a simult...

Страница 9: ...ATION IN A MOBILE HOME WARNING DO NOT INSTALL IN SLEEPING ROOM 1 Stove must be permanently bolted to the floor 2 Stove must have permanent outside air source 3 Stove must be permanently electrically g...

Страница 10: ...out of the opening a 1 clearance is all that is required ALCOVE CLEARANCE RECOMMENDATIONS ALCOVE THROUGH THE WALL INSTALLATION REQUIREMENTS The stove is approved for horizontal exhaust however we reco...

Страница 11: ...F Be careful not to dislodge the thimble Position stove not closer than 1 to the wall NOTE Make sure that you leave enough clearance between the wall and the back of the unit so that when you open the...

Страница 12: ...n Non Combustible Hearth Plate 6 Min Fresh Air Intake Optional With 90 Degree Elbow or Hood Clean Out Cover Tee 3 Min Wall Thimble Flashing Rain Cap Storm Collar 24 Min INSIDE VERTICAL PIPE WITH ROOF...

Страница 13: ...ombustible Hearth Plate Support Bracket Every 5 Feet 1 Min Keep Attic Insulation Away From Pipe THROUGH THE WALL VERTICAL PIPE INSTALLATION WITH TERMINATION THROUGH THE ROOF The Hearth Pad is not requ...

Страница 14: ...Do not operate unit with broken glass Do not substitute original factory glass You must use only factory authorized glass Do not slam door shut Do not strike glass Do not use abrasive cleaners Do not...

Страница 15: ...the way in when done Front View Left Front View Circuit Board Control Panel Open door to access the controls Manual Draft Adjustment Slide in or out to adjust the amount of draft flowing through the f...

Страница 16: ...his will give you another 3 minutes before fuel feeds in If the fire is burning too fast and the fuel is being burned up too quickly push the manual draft knob in a little to slow the fire down This s...

Страница 17: ...is over 2000 square feet or the weather is extremely cold The high heat setting is intended for use with wood pellets and the highest heat setting for corn would be the number 4 setting The unit is n...

Страница 18: ...he front of the stove will be extremely hot during operation Always wear heat resistant gloves to perform periodic maintenance Move the shaker grate in and out 10 times and return it to operating posi...

Страница 19: ...ash content and or significant debris in it your exhaust system will require weekly cleaning Cleaner fuels will allow for monthly cleaning of the exhaust system Remove the exhaust pipe from the back...

Страница 20: ...AUTOMATIC SAFETY FEATURES Power Outage During a power outage the stove will shut down safely It will not automatically restart when the power returns unless the exhaust is still up to temperature see...

Страница 21: ...male terminal connectors one for each wire from wall thermostat Back of Circuit Board It is a good idea to use the thermostat option to achieve uniform control over your heating needs If you are gone...

Страница 22: ...on page Change to a better grade of fuel if necessary See page 5 6 regarding fuel quality Check that damper control knob is adjusted properly Pull out to increase fire burn Check gasket seal around th...

Страница 23: ...y Auger circuit board pressure switch or relay Check contents of the hopper Add fuel if necessary Have your USSC reseller diagnose the problem and replace the part s Stove runs for 30 minutes and then...

Страница 24: ...nsert installation If the existing fireplace opening was not thoroughly cleaned and painted be fore the insert was installed then the convection fan may be picking up the fireplace dust soot or ash an...

Страница 25: ...USSC 25 WIRING DIAGRAM...

Страница 26: ...26 USSC REPAIR PARTS DIAGRAM 6033 1 3 4 5 17 24 25 2 6 51 52 49 57 41 43 40 39 50 53 54 55 56 38 44 45 37 32 33 34 35 48 30 31 29 47 42 36 26 27 28 12 11 46 7 10 9 8 23 22 21 20 16 19 15 13 18 14 58...

Страница 27: ...r Sprocket 1 31 80460 Terminal Block 1 N S 80464 Terminal Block Jumper 1 32 80381 Low Limit Switch F110 Thermodisc 60T12 1 33 80381 Distribution Blower Limit Switch F110 Thermodisc 60T12 1 34 80455 Au...

Страница 28: ...AYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION AS SHOWN IN THIS LIST 1 THE PART NUMBER 2 THE PART DESC...

Отзывы: