Supported Controllers and Matrix Switching Systems 

SpeedDome Optima may be used with the following controllers and matrix switching systems. See notes below for specific limitations or restrictions. 

Feature 

VM16 / 

ADTT16 

Series 

VM32 / 

AD32 Series 

VM96 

Series  

AD2150 / 

AD2350 

(1, 2)

 

MegaPower 

LT 

MegaPower 

48 

(1, 2)

 

AD1650  

(1, 2)

 

AD168  

(1, 2) 

AD2050  

(1, 2)

 

AD 

MegaPower 

1024 

(1, 2)

 

Supported 
Protocols 

SensorNet SensorNet RS-422 

SensorNet 

Manchester 
RS-422  

SensorNet 

Manchester 
RS-422 
SensorNet 

Manchester 
RS-422  

Manchester 
RS-422 
SensorNet 

Manchester 
RS-422  

Manchester 
RS-422  

Maximum 
Available 
Presets 

96 96 

Unlimited 

(3)

 

64

 Manchester 

16

 RS-422 

96 

64 

Manchester 

96 

RS-422 (6)

 

96 

SensorNet

 

64 

Manchester 

16 

RS-422

 

64 

Manchester 

64 

RS-422 (6)

64 

SensorNet

 

64 

Manchester

16 

RS-422

 

64 

Manchester 

16 

RS-422 

 

Maximum 
Available 
Patterns 

(4)

 

3 3 3 3 3 

3 3 3 3 3 

DirectSet 
menu 

(5)

 

Yes 

(7) 

No No No 

Yes 

(8) 

Yes 

(8) 

No No No No 

 

NOTES: 

(1)  For the list of compatible keyboards, see 

Supported AD Keyboards

 on page 5. 

(2)  RS-422 is supported with the appropriate code converter.  

(3)  Preset information is stored at the host, not the dome. 

(4)  Patterns are limited by time and the number of available dome commands. Total time for the patterns cannot exceed 6 minutes 50 seconds. 

Total number of dome commands used in the patterns cannot exceed 99. 

(5)  Although text overlay is not supported, the following DirectSet menu commands are supported: Return to Auto Iris/Focus, Flip, Peel and Dome 

Reset. See 

DirectSet Menu Commands

 on page 3 for more information. 

(6)  If the RS-422 Code Converter is used, only 16 presets are supported. 

(7)  Requires firmware version 0701-2833-0103 (EEPROM) / 0701-2834-0201 (Flash) or newer. 

(8)  Requires a compatible keyboard with a DirectSet key (ADCC0200 or ADCC0300). 

 

Содержание SpeedDome Optima

Страница 1: ... 3 Clearing Patterns 3 DirectSet Menu Commands 3 Supported Controllers and Matrix Switching Systems 4 Supported Dome Commands 5 Declarations 8 Sensormatic 2004 About this Guide This Quick Reference Guide explains the functions supported by the SpeedDome Optima programmable dome camera It is intended to supplement information included in the operator s manual for your video controller or matrix swi...

Страница 2: ...ported may differ for your controller Table 1 Protocols and supported features Feature SensorNet RS 422 Manchester Maximum Presets 96 a 96 a 64 Maximum Patterns 3 3 3 Resume Auto Focus Auto Iris b Yes Yes Yes Dome Reset Yes Yes Yes V Phase adjustment Yes Yes Yes Auxiliary output control Yes Yes Yes a The actual number of available presets may differ based on the controller used b Pressing the Iris...

Страница 3: ...attern for the selected pattern For more information about programming patterns refer to your controller operator s manual Note If Pattern 3 is cleared this removes the home position programming The dome will not automatically return to the specified preset or pattern after 10 minutes of dome inactivity Pattern Programming Summary Commands Result Start Pattern programming followed by stop Pattern ...

Страница 4: ... 6 64 SensorNet 64 Manchester 16 RS 422 64 Manchester 16 RS 422 Maximum Available Patterns 4 3 3 3 3 3 3 3 3 3 3 DirectSet menu 5 Yes 7 No No No Yes 8 Yes 8 No No No No NOTES 1 For the list of compatible keyboards see Supported AD Keyboards on page 5 2 RS 422 is supported with the appropriate code converter 3 Preset information is stored at the host not the dome 4 Patterns are limited by time and ...

Страница 5: ...et Shot Define Pattern 2 18 Set Shot Define Pattern 3 19 Set Shot End Pattern Definition 33 Set Shot Accept save New Pattern 34 Set Shot Go to Pattern 1 17 Call Shot Go to Pattern 2 18 Call Shot Dome Function Keyboard Command Go to Pattern 3 19 Call Shot Run Pattern 1 21 Call Shot Run Pattern 2 22 Call Shot Run Pattern 3 23 Call Shot Review Temporary Pattern 24 Call Shot Auto Repeat Pattern 1 25 C...

Страница 6: ... Definition 68 Shot Save New Pattern 69 Shot Clear Pattern 1 62 Shot Clear Pattern 2 63 Shot Clear Pattern 3 64 Shot Enter V phase Adjustment 67 Shot followed by iris open close Exit V phase Adjustment 67 Shot MegaPower 48 Matrix Switcher Controller System See Supported AD Keyboards for button names used on specific keyboards Dome Function Keyboard Command Define Pattern 1 121 F2 Define Pattern 2 ...

Страница 7: ...0 F1 Enter Vertical Phase Adjust Mode 38 F2 Exit Vertical Phase Adjust Mode 39 F2 In addition the following commands are not supported Set Auxiliary 4 OFF 70 F1 Set Auxiliary 4 ON 71 F1 Manchester Commands These commands are supported by systems using the Manchester protocol See Supported AD Keyboards for button names used on specific keyboards Verified with AD2050 AD2091 and AD168 with CCM v 3 01...

Страница 8: ...t is your point of contact if you have a need for service or support Our dealers are fully empowered to provide the very best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net NOTICE The information in this manual was current when published The manufacturer reserves the right to revise and improve its ...

Отзывы: