SIX BAY SYSTEMS, 128 CAMERAS x 16 MONITORS
Systems for a maximum of 128 cameras and 16 monitors are
supplied in six bays. The AD1653B bay contains a power
supply, processor, and monitor modules for monitors 1 through
8; the AD1657 bay contains a power supply and monitor
modules for monitors 9 through 16. The AD1654 bay contains
camera modules for cameras 1 through 64, for monitors 1
through 8; the AD1656 bay contains camera modules for
cameras 1 through 64, for monitors 9 through 16. The
AD1655 bay contains camera modules for cameras 65 through
128, for monitors 1 through 8; the AD1658 bay contains
camera modules for cameras 65 through 128, for monitors 9
through 16.
These systems are supplied in six bays configured as below:
AD1653B AD1654 AD1655
Modules/Panels
Bay
Bay
Bay
AD1603N PSM, Power Panel
1
-
1
Power Panel
-
1
-
AD1663B CPM, Data Panel
1
-
-
AD1611 VIM
-
8
1-8
AD1626 VOM
1-4
-
-
VIP Panel
-
1
1
AD1657 AD1656 AD1658
Modules/Panels
Bay
Bay
Bay
AD1603N PSM, Power Panel
1
-
1
Power Panel
-
1
-
AD1609 VIM
-
8
1-8
AD1626 VOM
1-4
-
-
VIP Panel
-
1
1
For illustration of a typical Six Bay system with 128 cameras
and 16 monitors, see Typical System Connections, page C-13.
IDENTIFY ALL BAYS, MODULES, AND PANELS
CAREFULLY BEFORE PROCEEDING.
Power/Data Interconnections
Two Power/Data Interconnect cables are supplied. Connect
one cable between connector J1 on the AD1603N PSM Power
Panel in the AD1653B bay and connector J1 on the Power
Panel in the AD1654 bay. The second Power/Data cable is
connected between connector J1 on the AD1603N PSM Panel
in the AD1657 bay and J1 on the AD1656 bay Power Panel.
Three Data Interconnect cables are supplied. Connect one
Data cable between connector J2 on the Data Panel in the
AD1653B bay and J2 on the Power Panel in the AD1655 bay.
Connect the next Data cable between connector J3 on the Data
Panel in the AD1653B bay and J3 on the Power Panel in the
AD1657 bay. Connect the remaining Data cable between
connector J4 on the Data Panel in the AD1653B bay and J4 on
the Power Panel in the AD1658 bay.
Control Code Connections
Control Code for cameras 1-64 is provided from flying leads
on the Power/Data cables, from either the AD1653B bay or the
AD1657 bay (the same code is available from both bays).
Control Code for cameras 65-128 is provided from connector
J1 on the Power Panel in either the AD1655 bay or the
AD1658 bay (the same code is available from both bays).
Video Interconnections
The eight video output BNC’s from the VIP Panels on the
AD1654 and AD1656 bays are for cameras 1 to 64 and the
eight output BNC’s on the VIP Panels on the AD1655 and
AD1658 bays are for cameras 65 to 128.
Each AD1626 VOM in the AD1653B and AD1657 bays has
two pairs of input BNC’s located on the upper portion of its
back panel, for video interconnections from the VIP panels.
Outputs from the VIP Panels in the AD1654 and AD1656 bays
connect to the AD1653B and AD1657 bays “A” MONITOR
BNC’s. Outputs from the VIP Panels in the AD1655 and
AD1658 bays connect to the AD1653B and AD1657 bays “B”
MONITOR BNC’s.
From the rear of the AD1653B bay, the input BNC for system
monitor 1 is located at the right-most VOM position in the bay,
labeled MONITOR 1 A and 1 B, and system monitor 2 is
labeled MONITOR 2 A and 2 B. System monitor 3 is on the
next panel to the left, labeled MONITOR 3A and 3 B, and
system monitor 4 is labeled MONITOR 4 A, and so on to
system monitor 8.
In the AD1657 bay, the input BNC for system monitor 9 is
located at the right-most VOM position in the bay, labeled
MONITOR 9 A and MONITOR 9 B, system monitor 10 is
labeled MONITOR 10 A and 10 B. System monitor 11 is on
the next panel to the left, labeled MONITOR 11 A and 11 B,
system monitor 12 is labeled MONITOR 12 A and 12 B, and
so on to system monitor 16.
(Continue the Video Interconnections on the next page.)
3-10
SYSTEM CONFIGURATIONS
AD1650B