![American Dynamics ADCI625-P221 Скачать руководство пользователя страница 115](http://html.mh-extra.com/html/american-dynamics/adci625-p221/adci625-p221_configuration-and-users-manual_2924041115.webp)
Information
8-105
8
Current Faults
Current Faults
When Current Faults is selected information will be displayed on the following:
•
#
- details the fault index.
•
Fault
- a description of the fault.
•
Date created
- the time and date when the fault occurred.
•
Component
- internal software component that raised the fault either DIOM (Digital Input Output
Monitor) or ENVM (Environmental Monitor).
•
Severity
- indicates how serious the fault is. The following are supported, in increasing order of
severity, Clear, Warning, Critical and Error.
•
Detail
- extra information that supplements the fault description.
•
Delete
-remove the fault from the fault table.
Fault Details
DIOM (Digital Input Output Monitor) Component
The following faults can be raised by the DIOM (Digital Input Output Monitor) component when
using the Illustra 625 PTZ Camera Feature Plus:
• DigitalAlarmInForce
• DigitalRaiseInputAlarm1
• DigitalRaiseInputAlarm2
• DigitalRaiseInputAlarm3
• DigitalRaiseInputAlarm4
System Faults
The following system faults may be raised:
•
DiskUsage(Warning)
- this warning is raised when the disk utilisation rises above the threshold
value “threshold2” held in SYSM.conf. Once an alarm is generated and the disk utilization
decreases 1% below the threshold value, the fault is then automatically cleared. The default
threshold value is 80%.
•
PowerSupplyAlarm(Error)
- this fault is raised when one or more of the internal DC power
supplies voltage level is either too high or too low. Once an alarm is generated and the DC
power voltage goes back into the proper range, the fault is then automatically cleared.
ENVM (Environmental Monitor) Component
If an environmental card is used the following faults can be raised by the ENVM (Environmental
Monitor) component:
•
BlowerConditionFaulty (Error)
- the blower condition may be GOOD or FAIL. Since the
environmental card hardware contains two blowers, the reported condition is the worst for both
blowers. Therefore, if one blower fails, but the other works correctly, the condition will be
reported as “Fail”.
Содержание ADCI625-P221
Страница 1: ...Configuration and User Guide Illustra 625 PTZ Camera 8200 0999 06 B0 ...
Страница 10: ...Table of Contents ii viii Configuration and User Guide ...
Страница 12: ...Introduction 1 2 Configuration and User Guide ...
Страница 14: ...Installation 2 4 Configuration and User Guide Installation Process ...
Страница 68: ...Programs Menu 5 58 Configuration and User Guide ...
Страница 79: ...Camera Configuration Menu 6 69 6 The selected stream will be used for video generated from an alarm End ...
Страница 118: ...Information 8 108 Configuration and User Guide ...
Страница 128: ...Technical Specifications 9 118 Configuration and User Guide ...
Страница 132: ...Appendix A User Account Access 10 122 Configuration and User Guide ...
Страница 133: ...11 123 B Appendix B Site Maps Overview of the Web GUI ...
Страница 134: ...Appendix B Site Maps 11 124 Configuration and User Guide View Menu ...
Страница 135: ...Appendix B Site Maps 11 125 B Programs Menu ...
Страница 136: ...Appendix B Site Maps 11 126 Configuration and User Guide Camera Configuration ...
Страница 137: ...Appendix B Site Maps 11 127 B Networking ...
Страница 138: ...Appendix B Site Maps 11 128 Configuration and User Guide Information ...
Страница 142: ...Appendix C Using VLC Player to View RTSP Streaming 12 132 Configuration and User Guide ...