American Dynamics AD2096A Скачать руководство пользователя страница 1

Installation and Operating Instructions

This manual describes the installation and operating procedures for the American Dynamics AD2096A Alarm Interface Unit.
The AD2096A Alarm Interface Unit, when used with American Dynamics Matrix Switching Systems, automatically calls
specified cameras and preset scenes to specified monitors when contacts are activated external to the system.
-
-

Model AD2096A

Alarm Interface Unit

Содержание AD2096A

Страница 1: ...the American Dynamics AD2096A Alarm Interface Unit The AD2096A Alarm Interface Unit when used with American Dynamics Matrix Switching Systems automatically calls specified cameras and preset scenes t...

Страница 2: ...is furnished to the purchaser under a license for use on a single system Information furnished by SENSORMATIC is believed to be accurate and reliable However no responsibility is assumed by SENSORMATI...

Страница 3: ...ed with the packing list with your order Be sure to save 1 The shipping cartons and insert pieces They are the safest material in which to make future shipments of the product 2 The IMPORTANT SAFEGUAR...

Страница 4: ......

Страница 5: ...Relay Output 3 RS 232 Connection 3 Cascading Multiple Units 3 OPERATION 4 Power Sources 4 Powering Up 4 Alarm Response Operation 4 Programming Alarm Contacts 4 TYPICAL SYSTEM CONNECTIONS AD2096A to AD...

Страница 6: ......

Страница 7: ...tilation See Figure 2 for illustration of the mounting options The AD2096A is shipped with mounting ears installed flush with the front panel and can be mounted to the front of a standard 19 rack The...

Страница 8: ...3 769 832 0 0 0 0 1 1 0 0 14 833 896 0 0 0 0 1 1 0 1 15 897 960 0 0 0 0 1 1 1 0 16 961 1024 0 0 0 0 1 1 1 1 Table 2 S2 Input Type Setup 0 OFF Normally Open NO 1 ON Normally Closed NC ALARM SWITCH ALAR...

Страница 9: ...003 0047 02 are supplied with each AD096A for connections to these ports The RS 232 port labeled COM OUTPUT is connected to a switching system input port or to another AD2096A AIU see Cascading below...

Страница 10: ...ies a maximum of 1024 alarm contacts ACN s can be programmed for alarm event response by that system When an alarm condition exists the AD2096A AIU detects the closure or opening of the contact depend...

Страница 11: ...Typical System Connections...

Страница 12: ......

Страница 13: ...4 5 6 7 8 K E Y B R D AD2096A SELECTS ALARM GROUP 1 64 65 128 129 192 etc NORMALLY OPEN CLOSED POSITION FOR ALARM INPUTS 1 8 9 16 17 24 etc 1 2 3 4 5 6 7 8 TERMINAL BOX 2113 0019 01 BROWN GRD GREEN R...

Страница 14: ...A A A A RST LAN 1 IN OUT LAN 2 IN OUT PORT 10 PORT 9 PORT 8 PORT 7 PORT 6 PORT 5 PORT 4 PORT 3 PORT 1 PORT 2 TYPICAL SYSTEM CONNECTIONS AD2096A TO AD1995 6003 0047 02 AD2096A AUX START RELAY OUTPUT BR...

Страница 15: ...1000 330m USING SHIELDED 18 AWG CABLE CABLE 6003 0047 02 FOR DIRECT CONNECTIONS UP TO 7 FEET 6003 0047 02 6003 0047 02 C 4 TYPICAL AD2096A CONNECTIONS TO AD1996 CPU WHEN THE UNITS ARE LESS THAN 7 APAR...

Страница 16: ...TANCE BETWEEN THE BOXES IS 1000 330m USING SHIELDED 18 AWG CABLE TYPICAL AD2096A CONNECTIONS TO AD2150 2350 SWITCHERS WHEN THE UNITS ARE LESS THAN 7 APART USE CABLE 6003 0047 02 WHEN DISTANCES EXCEED...

Страница 17: ...NNECTIONS UP TO 7 FEET 6003 0047 02 ABCDEFGH ON OFF SELECT ALARM POWER C O M INPUT OUTPUT ABCDEFGH N N C O C M 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 31 32 33 34 35 36 37 38 39 40 41 42 43...

Страница 18: ...27 26 25 49 50 51 52 53 54 7 8 9 10 11 12 31 32 33 34 35 36 55 56 57 58 59 60 15 13 14 16 17 18 37 38 39 40 41 42 61 62 63 64 19 20 21 22 23 24 43 44 45 46 47 48 120V 60Hz A A A A A A A A A A A A A A...

Страница 19: ...Index...

Страница 20: ......

Страница 21: ...m Relay Output 3 Cascading Multiple Units 3 RS 232 Connections 3 DESCRIPTION 1 FEATURES 1 Input Type Setup 2 INSTALLATION 1 OPERATION Alarm Response 4 Power Sources 4 Powering Up 4 Programming Alarm C...

Страница 22: ......

Страница 23: ...ions Safety EN 60950 1992 EMC EN 50130 4 1995 EN 55022 1994 Class B EN 61000 3 2 1995 EN 61000 3 3 1995 EN 61000 4 2 1995 EN 61000 4 3 1996 EN 61000 4 4 1995 EN 61000 4 5 1995 EN 61000 4 6 1996 EN 610...

Страница 24: ...2096 1 230 VAC 50 60 Hz 40 mA Alarm Inputs Contact Inputs 64 inputs each with contact and separate ground Open Circuit Voltage 5 0 VDC Closed Circuit Maximum Current 0 2 mA Maximum Resistance to Groun...

Отзывы: