IMPORTANT: The dryer must be connected to the electric
supply shown on the data label.  In the case of 208 VAC or
230/240 VAC, the supply voltage must match the electric
service specifications of the data label exactly.

NOTE: ADC reserves the right to make changes in
specifications at any time without notice or obligation.

Electrical Connections

NOTE: A wiring diagram is included with each dryer and is
located in the front control box area.

The only electrical input connections to the dryer are the
3-phase (3ø) power leads (L1, L2, and L3), GROUND, and
in the case of 4-wire service, the neutral.  Providing local
codes permit, power connections to the dryer can be made
by the use of a flexible underwriters laboratory listed cord/
pigtail (wire size must conform to rating of the dryer), or the
dryer can be hard wired directly to the service breaker.  In all
cases, a strain relief must be used where the wire(s) enter
the dryer electrical service (relay) box.

Gas Model and Steam Model Dryers

These electrical connections are made at the terminal block
located in the electric service/relay box at the rear, upper left
hand corner of the dryer.  To gain access into this service
box, the service cover (upper back guard) must be removed.

Electric Model Dryers

For electric model dryers made to operate at 208 VAC, or
230/240 VAC, the electrical input connection is made into
the terminal block located at the upper rear of the dryer (refer
to the illustration below).  For electric model dryers made to
operate at 380 VAC, 416 VAC, 440 VAC, or 480 VAC, the
electrical input connection is made to the oven relay located
at the upper rear of the dryer (refer to the illustration below).
Input connection wiring must be sized properly to handle
the dryer’s current draw.  This information is printed on the
dryer’s data label.

NOTE: A circuit servicing each dryer must be provided.

208 VAC and 230/240 VAC are not the same.  Any
damage done to dryer components due to
improper voltage connections will automatically
void the warranty.

 

WARNING

!

ELECTRIC

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

 

IMPORTANT

:

 

NOTES

: A.

 B.

 C.

208 VAC AND 230/240 VAC ARE NOT THE SAME.  When
ordering, specify exact voltage.

When fuses are used they must be dual element, time delay,
current limiting, class RK1 or RK5 ONLY.  Calculate/determine
correct fuse value, by applying either local and/or National

Electrical Codes to listed appliance amp draw data.

Circuit breakers are thermal-magnetic (industrial) type ONLY.

For others, calculate/verify correct breaker size according to

appliance amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.

SERVICE

VOLTAGE

PHASE

WIRE

SERVICE

APPROX.

AMP DRAW

CIRCUIT

BREAKER

60 Hz

50 Hz

72 kW

208

3

214

300

240

3

188

250

230

3

198

250

380

3

118

150

380

 4

*

118

150

400

 4

*

113

150

416

 4

*

108

150

460

3

98

125

480

3

94

125

575

3

78

100

75.6 kW

440

3

106

150

220

3

205

275

Содержание ML-130 III

Страница 1: ...s de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d incendie ou d explosion ou pour éviter tout dommage matériel toute blessure ou la mort Ne pas entreposer ni utiliser d essence ni d autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareils ...

Страница 2: ...___________________________________________________________________ SERIAL NUMBER S __________________________________________________________________________________ ____________________________________________________________________________________________________ ____________________________________________________________________________________________________ Replacement parts can be obtain...

Страница 3: ...e dryer in the presence of dry cleaning fumes Dryer must not be installed or stored in an area where it will be exposed to water or weather The wiring diagram for the dryer is located in the front electrical control box area List of Acronyms _____________________ D M S Drill Measurement Size DSI Direct Spark Ignition F S S Fire Suppression System HSI Hot Surface Ignition HVAC Heating Ventilating a...

Страница 4: ...r washed fabrics Do not dry articles spotted or washed in dry cleaning solvents a combustible detergent or all purpose cleaner Explosion could result Do not dry rags or articles coated or contaminated with gasoline kerosene oil paint or wax Explosion could result Do not dry mop heads Contamination by wax or flammable solvents will create a fire hazard WARNING WARNING Do not use heat for drying art...

Страница 5: ...___________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ______________...

Страница 6: ...APPROX NET WEIGHT 1 260 lb 571 53 kg APPROX SHIPPING WEIGHT 1 400 lb 635 03 kg AIRFLOW 60 Hz 2 150 cfm 60 88 cmm 50 Hz 1 792 cfm 50 73 cmm EXHAUST CONNECTION DIAMETER 14 35 56 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A OVEN SIZE kW Btu hr kcal hr 72 245 729 61 923 75 6 258 023 65 021 VOLTAGE AVAILABLE 208 575v 3ø 3 4w 50 60 Hz APPROX NET WEIGHT 1 421 lb 644 55 kg APPROX SHIPPING WE...

Страница 7: ...113335 12 www amdry com 7 ML 130 Specifications _____________________________________________________________ ...

Страница 8: ...260 lb 571 53 kg APPROX SHIPPING WEIGHT 1 400 lb 635 03 kg AIRFLOW 1 750 cfm 49 55 cmm HEAT INPUT 300 000 Btu hr 75 599 kcal hr EXHAUST CONNECTION DIAMETER 12 30 48 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A INLET PIPE CONNECTION 1 F N P T VOLTAGE AVAILABLE N A APPROX NET WEIGHT APPROX SHIPPING WEIGHT AIRFLOW EXHAUST CONNECTION DIAMETER COMPRESSED AIR CONNECTION COMPRESSED AIR VOLU...

Страница 9: ...113335 12 www amdry com 9 ML 130DR Specifications __________________________________________________________ ...

Страница 10: ...r to Dryer Enclosure Requirements Provisions must be made for adequate clearances for servicing and for operation as noted in this manual refer to Dryer Enclosure Requirements The dryer must be installed with a proper exhaust duct connection to the outside as noted in this manual refer to Exhaust Requirements The dryer must be located in an area where correct exhaust venting can be achieved as not...

Страница 11: ...closing of the control door along with the removal of panels during maintenance Even though a 12 inch 30 48 cm clearance is acceptable it is recommended that the rear of the dryer be positioned approximately 2 feet 0 61 meters from the nearest obstruction i e wall for ease of installation maintenance and service Bulkheads and partitions should be made from noncombustible materials The clearance be...

Страница 12: ...ich results in slow drying increased use of energy overheating of the dryer and shutdown of the burner by the airflow sail switch burner hi limit or tumbler hi heat thermostat The dryer must be installed with a proper exhaust duct connection to the outside CAUTION This dryer produces combustible lint and must be exhausted to the outdoors Improperly sized or installed exhaust ductwork can create a ...

Страница 13: ...ters or has numerous elbows the cross sectional area of the ductwork must be increased in proportion to the length and number of elbows in it IMPORTANT For extended ductwork runs the cross section area of the duct can only be increased to an extent When the ductwork approaches the maximum limits as noted in this manual a professional HVAC firm should be consulted for proper venting information Mul...

Страница 14: ...rcuit The dryer must be connected with copper wire only Do not use aluminum wire which would cause a fire hazard The copper conductor wire cable must be of proper ampacity and insulation in accordance with electric codes for making all service connections NOTE The use of aluminum wire will void the warranty Wiring diagrams are affixed to the inside at the top front control door and to the rear upp...

Страница 15: ...t connection is made into the terminal block located at the upper rear of the dryer refer to the illustration below For electric model dryers made to operate at 380 VAC 416 VAC 440 VAC or 480 VAC the electrical input connection is made to the oven relay located at the upper rear of the dryer refer to the illustration below Input connection wiring must be sized properly to handle the dryer s curren...

Страница 16: ...or hot water pipe The grounded cold water pipe must have metal to metal connections all the way to electrical ground If there are any nonmetallic interruptions such as a meter pump plastic rubber or other insulating connectors they must be jumped out with no 4 copper wire and securely clamped to bare metal at both ends IMPORTANT For personal safety and proper operation the dryer must be grounded F...

Страница 17: ... gas pressure regulators meet applicable pressure requirements and that gas meters be rated for the total amount of all the appliance Btu being supplied The dryer is provided with a 1 N P T inlet pipe connection extending out the back area of the burner box The minimum pipe size connection supply line to the dryer is 1 diameter For ease of servicing the gas supply line of each dryer must have its ...

Страница 18: ...formance and can cause component failure Clean dry and regulated steam must be provided to the dryer IMPORTANT Steam coil failure due to water hammer by wet steam will void the warranty The pressure of the condensate in the steam supply line will cause water hammer and subsequent heat exchanger steam coil failure The steam supply connection into the main supply line must be made within a minimum 1...

Страница 19: ...ine just before the dryer connection This is necessary to ensure that correct and clean air pressure is achieved Steam Damper System Operation The steam damper as shown in the illustration below allows the coil to stay constantly charged eliminating repeated expansion and contraction When the damper is opened the air immediately passes through the already hot coil providing instant heat to start t...

Страница 20: ... marginal location installation conditions Turn on electric power to the dryer Make sure the main door is closed and the lint drawer is securely in place Refer to the Operating Instructions for starting your particular model dryer Check to ensure that the tumbler starts in the clockwise direction Additionally check the direction of the blower motor impellor fan to ensure that the blower motor impe...

Страница 21: ...op during travel If either of these conditions occur the flow control must be adjusted Refer to the Cool Down Mode in bottom illustration on page 19 for air adjustment instructions Make a complete operational check of all safety related circuits i e lint drawer switch and sail switch on gas models Reversing tumbler dryers should never be operated with less than an 80 lb 36 3 kg load dry weight sin...

Страница 22: ...leted and returned for each individual dryer NOTE Be sure to include the installation date when returning the warranty card s Warranty For a copy of the ADC commercial warranty covering your particular dryer s contact the ADC reseller from whom you purchased the equipment and request a dryer warranty form If the reseller cannot be contacted or is unknown warranty information can be obtained from t...

Страница 23: ...exhaust ducting and remove any lint buildup Suggested Cleaning Schedule Daily beginning of each work shift Clean lint from screen Inspect lint screen and replace if torn Weekly Clean lint accumulation from lint chamber thermostat and microprocessor temperature sensor sensor bracket area Lint from most fabrics is highly combustible The accumulation of lint can create a potential fire hazard Keep dr...

Страница 24: ...ing American Dryer Corporation certain information is required to ensure proper service parts information from ADC This information is on the data label located on the left side panel wall area behind the control door When contacting ADC please have the model number and serial number available 1 Model Number Describes the size of the dryer and the type of heat gas electric or steam 2 Serial Number...

Страница 25: ...trials If the flame is not sensed at the end of the third retry trial inter purge period of 30 seconds the DSI module will LOCKOUT L E D diagnostic indicator flashes A steady L E D indicator indicates normal operation No L E D indicator indicates a power or an internal failure has occurred For Models with DSI Module Type II Theory of Operation Start the drying cycle When the gas burner ignites wit...

Страница 26: ...TANT It is your responsibility to have all plumbing connections made by a qualified professional to ensure that the plumbing installation is adequate and conforms to local state and federal regulations or codes It is the installer s or owner s responsibility to see that the necessary or required water water pressure pipe size or connections are provided The manufacturer assumes no responsibility i...

Страница 27: ...ill be inoperative WARNING Notes ______________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ _______...

Страница 28: ...ADC Part No 113335 12 07 31 08 5 ...

Отзывы: