background image

ProbleM

unit will not run

cauSe

1) No air supply to unit.

2) faulty air supply line.

SolutioN

1) connect air supply.

2) Perform maintenance and check line to air

supply.

unit runs but fan
makes loud scraping
noise.

unit runs but vibrates
excessively.

unit runs but fan does
not turn.

unit runs but does not
develop full power.

1) unit has been severely jolted

causing fan to rub against
housing.

2) unit has been severely jolted

causing housing to deform.

1) Severe jolt has bent motor shaft

causing unit to be out of
balance.

2) fan blade damaged.

3) Dirt built up on one side of fan

blade.

1) fan is jammed.

2) housing has been damaged and

presses on the fan blade.

1) low air supply pressure.

2) low air supply cfm.

3) excessive duct length.

4) Worn motor vanes.

1) remove motor and replace damaged motor

mounts.

2) Perform maintenance and check line to air

supply.

1) remove and replace motor. replace fan

blade as necessary.

2) replace fan blade.

3) clean fan blade.

1) remove motor and replace damaged motor

mounts.

2) replace fan blade if necessary.

3) replace housing/unit as necessary.

1) Supply 100 psi air.

2) increase size of compressor and/or size of

supply lines to provide at least 71 cfm.

3) reduce duct length to recommended

maximum.

4) rebuild motor.

GENERAL TROUBLE SHOOTING GUIDE

ruNS GooD

theN SloWS

DoWN

ruNS

hot

WoN’t ruN

at all

loW

SPeeD

loW

torque

reaSoN

MOTOR TROUBLE SHOOTING GUIDE

Dirt, foreign Material

x

x

x

internal rust

x

x

x

Misalignment

x

x

x

x

x

insufficient air Pressure

x

x

too Small of air line

x

x

restricted exhaust

x

Poor lubrication

x

x

x

x

jammed Machine

x

x

x

x

compressor too Small

x

x

compressor too far 

from unit

x

x

7

Содержание VAF-3000P

Страница 1: ... in Class I Groups A B C and D Class II Groups E F and G and Class III Purchase Date_______________________ Serial No _______________________ Dealer_____________________________________________________________ Americ Corporation 785 Bonnie Lane Elk Grove Village IL 60007 USA Phone 847 364 4646 Fax 847 364 4695 ...

Страница 2: ...rms and obligations 1 introduction 2 General Safety information and operation 3 exploded View of the Vaf 3000P 4 Parts list 5 air Motor Precautions and operating Specs 6 trouble Shooting 7 lubrication and Servicing the air Motor 8 ...

Страница 3: ... beyond americ s control this limited warranty does not apply if the serial number has been removed obliterated or defaced americ corporation reserves the right to make changes to the Vane axial fan in design materials or specifications as necessary and without prior notice americ shall not be obliged to make alterations or modifications to existing products previously manufactured to obtain repla...

Страница 4: ...y does exist however that the Vane axial fan can be subjected to applications not intended by americ Misuse and or misapplication of the Vane Axial Fan can lead to the possibility of serious damage injury or even death anyone operating the Vane axial fan should refer to current oSha job safety and health rules and regulations pertaining to the construction industry with a particular emphasis on 29...

Страница 5: ...zarDouS locatioNS 1 CAUTION Ground unit at lug on coupler plate 2 Air supply lines shall be made of electrically conductive material in accordance with the recommended practice on static electricity NFPA 77 and or any other applicable local code INSTRUCTIONS FOR OPERATION AND CARE oPeratioN StaNDarDS your new Vaf 3000P comes to you completely assembled and ready to operate carefully inspect unit f...

Страница 6: ...VAF 3000P PICTORIAL BREAKDOWN 4 ...

Страница 7: ...6 17 00852a fan blade 17 104 50028 1 2 oD tube 18 104 50032 Muffler 19 Motor assembly 104 50014 Motor 104 50015 Motor Mount 104 50016 Motor endplate 104 50017 Motor bolt 104 50018 lock Washer 09 00889a Vane 104 50020 Vane to Motor bolts 104 50021 Star Washer 104 50022 lock Washer 104 50023 Nut 20 Motor connection 104 50025 Pipe Nipple 104 50026 hex bushing 104 50027 90 Swivel Slip on 21 03 00983a ...

Страница 8: ...in excess of the recommended operating maximums below ambient temperature should not exceed 121 c 250 f SAFETY SYMBOL When you see this symbol CAUTION be aware that personal injury or property damage is possible the hazard is explained in the text following the symbol CAUTION Severe personal injury or death coulD occur if hazard is ignored iNterNal oPeratiNG MaxiMuMS Motor Maximum Maximum Maximum ...

Страница 9: ...uct length 4 Worn motor vanes 1 remove motor and replace damaged motor mounts 2 Perform maintenance and check line to air supply 1 remove and replace motor replace fan blade as necessary 2 replace fan blade 3 clean fan blade 1 remove motor and replace damaged motor mounts 2 replace fan blade if necessary 3 replace housing unit as necessary 1 Supply 100 psi air 2 increase size of compressor and or ...

Страница 10: ...foreign material exiting the air motor can be hazardous Solid or liquid material exiting the unit can cause eye or skin damage Keep away from air stream Keep face away from exhaust port eye protection is required CAUTION flush unit only in a well ventilated area relubricate the motor by squirting a drop of oil in the chamber if the vanes need replacing or foreign materials are present in motor cha...

Страница 11: ...cing you Disconnect air hoses from the motor by pushing in on the ferrule lock ring while pulling on hoses Step three use a 13 16 open end wrench to spin off brass hex fittings from the air motor Note a 3 4 open end wrench may also be needed to spin off air connection ferrules of the 90º elbow because of limited space Step four lay unit down with the fan blade facing up remove the nylon nut that h...

Страница 12: ...al assistance REINSTALLING THE AIR MOTOR INTO THE VAF 3000P HOUSING Step one Prepare motor for installation by removing the shipping plugs from the air motor ports lay the Vaf 3000P face down on a firm work surface Step two carefully position air motor into the housing assembly with the motor shaft through the front mounting plate be sure to align the air fitting holes of the motor and housing so ...

Страница 13: ...t ring and grounding stud ring to the front of the unit s housing assemble bolt with flat washer first then the ground stud ring and finally the star washer this bolt assembly is then threaded through the grill and duct ring into unit s housing repeat steps to install grill duct ring and grounding stud ring to the rear of unit s housing you should use a 1 4 ratchet and a 7 32 socket for this proce...

Страница 14: ...785 Bonnie Lane Elk Grove Village IL 60007 Tel 847 364 4646 800 364 4642 Fax 847 364 4695 Email sales americ com www americ com ...

Отзывы: