AIR MOTOR PRECAUTIONS
CAUTION:
the air motor is designed to be driven by compressed air. under no circumstances should
the air motor be driven by any other gasses. the air motor must not be driven by fluids,
particles, solids or any substance mixed with air, particularly combustible substances likely
to cause explosion.
CAUTION:
Do Not uSe KeroSeNe or other coMbuStible SolVeNtS.
CAUTION:
foreign material exiting the air motor can be hazardous. Solid or liquid material exiting the
unit can cause eye or skin damage. Keep away from air stream.
CAUTION:
Keep face away from exhaust port. eye protection is required.
CAUTION:
Water, vapor, oil-based contaminates or other liquids must be filtered out.
CAUTION:
Do not drive the air motor in excess of the recommended operating maximums below.
ambient temperature should not exceed 121°c (250°f).
SAFETY SYMBOL
When you see this symbol,
CAUTION,
be aware that personal injury or property damage is possible.
the hazard is explained in the text following the symbol.
CAUTION:
Severe personal injury or death coulD occur if hazard is ignored.
iNterNal oPeratiNG MaxiMuMS
Motor
Maximum
Maximum
Maximum torque
Maximum air
Size
rPM
Pressure
in lb. - inch
consumption
(psig)
in cfm.
V4
3000
100
36.29
78
CAUTION:
Do not allow the air motor to “run free” at high speeds without a load. excessive internal
heat build up will result in loss of internal clearance and rapid motor damage.
cfM ratiNGS
free air
2063 cfm.
15' Straight Duct
1753 cfm.
15' 1-90
° bend
1616 cfm.
25' Straight Duct
1619 cfm.
25' 1-90
° bend
1497 cfm.
25' 2-90
°
bend
1433 cfm.
100' Straight blowing
1243 cfm.
CAUTION: Always disconnect the unit from the air supply before servicing.
6
Содержание VAF-3000P
Страница 6: ...VAF 3000P PICTORIAL BREAKDOWN 4 ...