REINSTALLATION PROCEDURES CONTINUED

Step Six:

Stand unit on its base once again with the motor shaft towards you. use a 13/16” open end wrench
to  tighten  the  90º  hose  fittings  onto  the  brass  hex  nipples  previously  installed  onto  the  motor
through the motor housing. be sure to coat threaded joints with loctite #545 Pneumatic Seal or
equivalent product to assure leak free installation of air hose fitting. attach hose to the fittings by
pushing onto ferrule until they snap-lock into place. tug on hose gently. if hoses release, push
more firmly into the ferrule until you hear it snap lock into place.

Note: orient the unit so the back of the motor is facing you. install the hose on the left into the top air motor

fitting. install the hose on the right into the bottom air motor fitting.

Step Seven: test air connections by attaching unit to air supply line. inspect hose connections for leaks. if a

leak is found, repeat sealing instructions outlined in Step Six.

CAUTION:

Never touch the spinning motor shaft – Severe personal injury will result.

Step eight: lay  unit  down  with  the  motor  shaft  facing  up.  install  fan  blade  with  the  flat  part  of  the  shaft

aligned with the flat guide on the fan hub. Place 3/8” flat washer on top of the fan hub before
securing  the  nut  on  the  shaft  with  a  9/16”  open  end  wrench. tighten  until  you  see  one  thread
exposed above the installed nylon nut. you may need to hold the blade by wedging it to prevent
rotation during this procedure.

CAUTION:

Never operate the unit with the fan blade installed without first installing the safety grills –
Severe personal injury will result.

Step Nine: install grill, duct ring and grounding stud ring to the front of the unit’s housing. assemble bolt

with flat washer first, then the ground stud ring and finally the star washer. this bolt assembly is
then threaded through the grill and duct ring into unit’s housing. repeat steps to install grill, duct
ring and grounding stud ring to the rear of unit's housing. you should use a 1/4” ratchet and a
7/32” socket for this procedure.

Note: there are three bolts used to attach each grill and duct ring. the longer of the three bolts is used to

attach the grounding stud ring to the unit’s housing.

CAUTION:

be sure to reattach flat washer, grounding wire stud ring and star washer to insure proper
ground continuity of the unit.

Step ten:

connect completely reassembled fan to air supply line and preform a final inspection of unit to
insure proper operation.

Step eleven:insure ground continuity with a multi meter. test with one lead attached to the grounding stud,

located  on  the  coupler  plate,  and  complete  the  circuit  by  touching  the  secondary  lead  to  the
following points while noting meter response:

1. the rivet holding the right side of the safety label in place.
2. the upper left corner rivet holding serial plate in place.
3. any coupler plate rivet.
4. the front and rear grills. test one of the bolts not connected to the ground wire.
5. back of motor. (long probe will be required to make contact.)

Note: Some resistance may be present when testing various points. the objective of this test is to assure that

all wires removed are properly reattached.

CAUTION:

this unit is ul/cul listed for use in hazardous locations. the grounding system links metal
components  together.  if  you  fail  to  properly  reattach  grounding  stud  rings,  washers,  star
washers and bolts, static electric build-up can result. the ul/cul listing for this unit will
also be null and void.

11

Содержание VAF-3000P

Страница 1: ... in Class I Groups A B C and D Class II Groups E F and G and Class III Purchase Date_______________________ Serial No _______________________ Dealer_____________________________________________________________ Americ Corporation 785 Bonnie Lane Elk Grove Village IL 60007 USA Phone 847 364 4646 Fax 847 364 4695 ...

Страница 2: ...rms and obligations 1 introduction 2 General Safety information and operation 3 exploded View of the Vaf 3000P 4 Parts list 5 air Motor Precautions and operating Specs 6 trouble Shooting 7 lubrication and Servicing the air Motor 8 ...

Страница 3: ... beyond americ s control this limited warranty does not apply if the serial number has been removed obliterated or defaced americ corporation reserves the right to make changes to the Vane axial fan in design materials or specifications as necessary and without prior notice americ shall not be obliged to make alterations or modifications to existing products previously manufactured to obtain repla...

Страница 4: ...y does exist however that the Vane axial fan can be subjected to applications not intended by americ Misuse and or misapplication of the Vane Axial Fan can lead to the possibility of serious damage injury or even death anyone operating the Vane axial fan should refer to current oSha job safety and health rules and regulations pertaining to the construction industry with a particular emphasis on 29...

Страница 5: ...zarDouS locatioNS 1 CAUTION Ground unit at lug on coupler plate 2 Air supply lines shall be made of electrically conductive material in accordance with the recommended practice on static electricity NFPA 77 and or any other applicable local code INSTRUCTIONS FOR OPERATION AND CARE oPeratioN StaNDarDS your new Vaf 3000P comes to you completely assembled and ready to operate carefully inspect unit f...

Страница 6: ...VAF 3000P PICTORIAL BREAKDOWN 4 ...

Страница 7: ...6 17 00852a fan blade 17 104 50028 1 2 oD tube 18 104 50032 Muffler 19 Motor assembly 104 50014 Motor 104 50015 Motor Mount 104 50016 Motor endplate 104 50017 Motor bolt 104 50018 lock Washer 09 00889a Vane 104 50020 Vane to Motor bolts 104 50021 Star Washer 104 50022 lock Washer 104 50023 Nut 20 Motor connection 104 50025 Pipe Nipple 104 50026 hex bushing 104 50027 90 Swivel Slip on 21 03 00983a ...

Страница 8: ...in excess of the recommended operating maximums below ambient temperature should not exceed 121 c 250 f SAFETY SYMBOL When you see this symbol CAUTION be aware that personal injury or property damage is possible the hazard is explained in the text following the symbol CAUTION Severe personal injury or death coulD occur if hazard is ignored iNterNal oPeratiNG MaxiMuMS Motor Maximum Maximum Maximum ...

Страница 9: ...uct length 4 Worn motor vanes 1 remove motor and replace damaged motor mounts 2 Perform maintenance and check line to air supply 1 remove and replace motor replace fan blade as necessary 2 replace fan blade 3 clean fan blade 1 remove motor and replace damaged motor mounts 2 replace fan blade if necessary 3 replace housing unit as necessary 1 Supply 100 psi air 2 increase size of compressor and or ...

Страница 10: ...foreign material exiting the air motor can be hazardous Solid or liquid material exiting the unit can cause eye or skin damage Keep away from air stream Keep face away from exhaust port eye protection is required CAUTION flush unit only in a well ventilated area relubricate the motor by squirting a drop of oil in the chamber if the vanes need replacing or foreign materials are present in motor cha...

Страница 11: ...cing you Disconnect air hoses from the motor by pushing in on the ferrule lock ring while pulling on hoses Step three use a 13 16 open end wrench to spin off brass hex fittings from the air motor Note a 3 4 open end wrench may also be needed to spin off air connection ferrules of the 90º elbow because of limited space Step four lay unit down with the fan blade facing up remove the nylon nut that h...

Страница 12: ...al assistance REINSTALLING THE AIR MOTOR INTO THE VAF 3000P HOUSING Step one Prepare motor for installation by removing the shipping plugs from the air motor ports lay the Vaf 3000P face down on a firm work surface Step two carefully position air motor into the housing assembly with the motor shaft through the front mounting plate be sure to align the air fitting holes of the motor and housing so ...

Страница 13: ...t ring and grounding stud ring to the front of the unit s housing assemble bolt with flat washer first then the ground stud ring and finally the star washer this bolt assembly is then threaded through the grill and duct ring into unit s housing repeat steps to install grill duct ring and grounding stud ring to the rear of unit s housing you should use a 1 4 ratchet and a 7 32 socket for this proce...

Страница 14: ...785 Bonnie Lane Elk Grove Village IL 60007 Tel 847 364 4646 800 364 4642 Fax 847 364 4695 Email sales americ com www americ com ...

Отзывы: