REMOVAL PROCEDURES CONTINUED

Step Six:

flip unit over on its back and remove the front motor assembly bolts with a 7/16” socket.

Step Seven:  use a 9/16” deep socket to remove the remaining brass hex fittings from the motor.

Step eight: rotate unit 180º onto its face. remove the three rear motor assembly bolts with the 7/16” socket.

fish out the rear motor end plate with an offset screw driver.

Note: a grounding wire is attached to the end plate bolt located between the two air motor fittings.

CAUTION:

be  sure  to  note  the  location  of  all  grounding  wires,  wahsers  and  star  washers  before
removing.  reattached  assemblies  to  the  same  location  from  which  they  were  removed  in
order to safeguard proper ground continuity.

Step Nine: the motor is now detached from the mounting assembly. carefully slip out of the housing for

repair. tape over the air fittings holes to prevent debris from falling into the motor while it is out
of the housing.

Step ten:

Decide if you want to ship the motor to the factory for repair, order a service kit that you can
install or purchase a new motor. Please contact the factory at the number listed on the front of this
manual to obtain parts, secure a return authorization or receive technical assistance.

REINSTALLING THE AIR MOTOR INTO THE VAF-3000P HOUSING

Step one:

Prepare motor for installation by removing the shipping plugs from the air motor ports. lay the
Vaf-3000P face down on a firm work surface.

Step two:

carefully  position  air  motor  into  the  housing  assembly  with  the  motor  shaft  through  the  front
mounting plate. be sure to align the air fitting holes of the motor and housing so that the fittings
can be installed into the motor through the housing.

Step three: coat threaded joints with loctite #545 Pneumatic Seal or equivalent product to insure leak free

installation of air fittings. install the two brass hex nipples into the air motor and tighten with a
9/16” deep socket.

Step four: Stand unit on base with front facing you. attach motor to front housing plate with three 7/16”

bolts  while  maneuvering  the  motor  into  position  from  the  rear.  tighten  securely  with  a  7/16”
socket.

Step five:

lay unit with the rear of motor facing up. install
the rear end plate by using a nail or other object
to  align  end  plate,  grounding  stud  ring  and
threaded hole.

Note: the  bolt  to  which  the  grounding  wire  must  be

attached  is  located  between  the  two  air  fittings.
Secure the three mounting bolts by tightening with a
7/16” socket.

CAUTION:

failure to reattach grounding stud ring to the same location from which it was removed will
break ground continuity and allow the accumulation of static electricity.

10

Содержание VAF-3000P

Страница 1: ... in Class I Groups A B C and D Class II Groups E F and G and Class III Purchase Date_______________________ Serial No _______________________ Dealer_____________________________________________________________ Americ Corporation 785 Bonnie Lane Elk Grove Village IL 60007 USA Phone 847 364 4646 Fax 847 364 4695 ...

Страница 2: ...rms and obligations 1 introduction 2 General Safety information and operation 3 exploded View of the Vaf 3000P 4 Parts list 5 air Motor Precautions and operating Specs 6 trouble Shooting 7 lubrication and Servicing the air Motor 8 ...

Страница 3: ... beyond americ s control this limited warranty does not apply if the serial number has been removed obliterated or defaced americ corporation reserves the right to make changes to the Vane axial fan in design materials or specifications as necessary and without prior notice americ shall not be obliged to make alterations or modifications to existing products previously manufactured to obtain repla...

Страница 4: ...y does exist however that the Vane axial fan can be subjected to applications not intended by americ Misuse and or misapplication of the Vane Axial Fan can lead to the possibility of serious damage injury or even death anyone operating the Vane axial fan should refer to current oSha job safety and health rules and regulations pertaining to the construction industry with a particular emphasis on 29...

Страница 5: ...zarDouS locatioNS 1 CAUTION Ground unit at lug on coupler plate 2 Air supply lines shall be made of electrically conductive material in accordance with the recommended practice on static electricity NFPA 77 and or any other applicable local code INSTRUCTIONS FOR OPERATION AND CARE oPeratioN StaNDarDS your new Vaf 3000P comes to you completely assembled and ready to operate carefully inspect unit f...

Страница 6: ...VAF 3000P PICTORIAL BREAKDOWN 4 ...

Страница 7: ...6 17 00852a fan blade 17 104 50028 1 2 oD tube 18 104 50032 Muffler 19 Motor assembly 104 50014 Motor 104 50015 Motor Mount 104 50016 Motor endplate 104 50017 Motor bolt 104 50018 lock Washer 09 00889a Vane 104 50020 Vane to Motor bolts 104 50021 Star Washer 104 50022 lock Washer 104 50023 Nut 20 Motor connection 104 50025 Pipe Nipple 104 50026 hex bushing 104 50027 90 Swivel Slip on 21 03 00983a ...

Страница 8: ...in excess of the recommended operating maximums below ambient temperature should not exceed 121 c 250 f SAFETY SYMBOL When you see this symbol CAUTION be aware that personal injury or property damage is possible the hazard is explained in the text following the symbol CAUTION Severe personal injury or death coulD occur if hazard is ignored iNterNal oPeratiNG MaxiMuMS Motor Maximum Maximum Maximum ...

Страница 9: ...uct length 4 Worn motor vanes 1 remove motor and replace damaged motor mounts 2 Perform maintenance and check line to air supply 1 remove and replace motor replace fan blade as necessary 2 replace fan blade 3 clean fan blade 1 remove motor and replace damaged motor mounts 2 replace fan blade if necessary 3 replace housing unit as necessary 1 Supply 100 psi air 2 increase size of compressor and or ...

Страница 10: ...foreign material exiting the air motor can be hazardous Solid or liquid material exiting the unit can cause eye or skin damage Keep away from air stream Keep face away from exhaust port eye protection is required CAUTION flush unit only in a well ventilated area relubricate the motor by squirting a drop of oil in the chamber if the vanes need replacing or foreign materials are present in motor cha...

Страница 11: ...cing you Disconnect air hoses from the motor by pushing in on the ferrule lock ring while pulling on hoses Step three use a 13 16 open end wrench to spin off brass hex fittings from the air motor Note a 3 4 open end wrench may also be needed to spin off air connection ferrules of the 90º elbow because of limited space Step four lay unit down with the fan blade facing up remove the nylon nut that h...

Страница 12: ...al assistance REINSTALLING THE AIR MOTOR INTO THE VAF 3000P HOUSING Step one Prepare motor for installation by removing the shipping plugs from the air motor ports lay the Vaf 3000P face down on a firm work surface Step two carefully position air motor into the housing assembly with the motor shaft through the front mounting plate be sure to align the air fitting holes of the motor and housing so ...

Страница 13: ...t ring and grounding stud ring to the front of the unit s housing assemble bolt with flat washer first then the ground stud ring and finally the star washer this bolt assembly is then threaded through the grill and duct ring into unit s housing repeat steps to install grill duct ring and grounding stud ring to the rear of unit s housing you should use a 1 4 ratchet and a 7 32 socket for this proce...

Страница 14: ...785 Bonnie Lane Elk Grove Village IL 60007 Tel 847 364 4646 800 364 4642 Fax 847 364 4695 Email sales americ com www americ com ...

Отзывы: