H
OMING
AN
AMCI N
ETWORKED
D
RIVER
Definition of Home Position
The Home Position is any position on your machine that you can sense and stop at. Once at the Home Posi-
tion, the motor position register of a Networked Driver must be set to an appropriate value. If you use the
unit’s
CW/CCW Find Home
commands, the motor position register will automatically be set to zero once the
home position is reached.
The Encoder Position register will also be reset to zero if the encoder is available
and enabled.
Defining a Home Position is completely optional. Some applications, such as those that use a
Networked Driver for speed control, don’t require position data at all.
With the exception of Absolute Moves, a Networked Driver can still perform all of its move commands if the
Home Position is not defined.
Position Preset
One of the ways to define the Home Position is to issue the Preset Position command to the Networked
Driver. On units with integral encoders, both the motor position and the encoder position can be preset sepa-
rately, and the motor position can also be preset to the encoder position. The motor and encoder position val-
ues can be preset anywhere in the range of –8,388,607 to +8,388,607.
CW/CCW Find Home Commands
The other choice is to use the driver’s Find Home commands to order the Networked Driver to find the Home
Position based on sensors brought into the unit. The CW Find Home command begins searching by rotating
the motor shaft in the positive direction and ends when the home sensor triggers while the Networked Driver
is rotating in the positive direction at the starting speed. The CCW Find Home command operates in the same
way but starts and ends with motion in the negative direction.
Homing Inputs
Four inputs can be used when homing the driver. These inputs are either physical inputs attached to the unit or
bits in the network output data words.
Physical Inputs
Home Input:
This input is used to define the actual home position of the machine.
CW Limit Switch Input:
This input is used to prevent overtravel in the clockwise direction.
CCW Limit Switch Input:
This input is used to prevent overtravel in the counter-clockwise direction.
Backplane Inputs
Backplace_Proximity_Bit:
A Networked Driver can be configured to ignore changes on the physical
homing input until the Backplace_Proximity_Bit makes a 0
1 transition. The Networked Driver will
home on the next inactive-to-active change on the physical input once this transition occurs. You must
program your host to control the state of this bit.
This chapter explains the various ways of homing a Networked Driver. Inputs used
to home the unit are introduced and diagrams that show how the unit responds to
a homing command are given.
Содержание SD17060E2
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S172 E2 Technology E2 Technology...
Страница 10: ...ABOUT THIS MANUAL Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 10 Notes...
Страница 22: ...UL CUL RECOGNIZED INSTALLATIONS Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 22 Notes...
Страница 54: ...CALCULATING MOVE PROFILES Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 54 Notes...
Страница 88: ...COMMAND MODE DATA FORMAT Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 88 Notes...
Страница 106: ...INSTALLING AN AMCI NETWORKED DRIVER Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 106 Notes...
Страница 130: ...ETHERNET IP EXPLICIT MESSAGING Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 130 Notes...
Страница 134: ...MODBUS TCP CONFIGURATION Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 134 Notes...
Страница 144: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...