CHAPTER 4
INSTALLING THE SD17060E
Outline Drawing
There are two ways to
mount the SD17060E.
The first method is with
four #10-32 screws into
its side panel.
Minimum and maxi-
mum screw lengths
should be observed to
prevent a screw from
shorting to the PC
Board.
The second method is by
the mounting tabs.
Mounting tabs are for #6
screws.
There are airflow holes
in the top and bottom of
the enclosure. To ensure
adequate convectional
airflow, the drive must
be mounted in the orien-
tation shown in the
drawing.
Airflow and Wiring Space
To ensure adequate airflow and wiring space, you need two inches (50 mm) of space above and below the
drive, one and one-half inches (37 mm) of space to the left and right of the drive, and one inch (25 mm) of
space in front of the drive. These dimensions are typical for convectional cooling. If you have an active cool-
ing system such as enclosure fans, you will be able to mount the drives closer together.
This chapter gives detailed information on installing the SD17060E. The person responsible for
installing the SD17060E should be familiar with the general installation guidelines given in the
previous chapter.
INPUT 1 +
INPUT 1
INPUT 2
INPUT 3
OUTPUT 1
INPUT 2
INPUT 3
OUTPUT 1
INTERLOCK
B CTAP
EARTH GND
A CTAP
INTERLOCK
B
B
A
A
GND
N
L
STEP/FAULT
POWER
+
+
+
AC POWER
95 – 132 V
AC
50/60 Hz
2.05"
(52.1)
1.10"
(27.9)
0.118"
(4.78)
0.152"
(3.86)
dia.
0.312"
(7.92)
dia.
6.71"
(170.4)
0.152"
(3.86)
typ.
1.000"
(25.40)
0.60"
(15.2)
6.15"
(156.2)
4.00" (101.6)
4.000"
(101.60)
1.073"
(27.25)
0.875"
(22.23)
7.00"
(177.8)
2.750" (69.85)
#10-32 UNF-2B.
Four places.
Min. screw length = 0.31"
(7.9)
+ thickness of mounting panel.
Max. screw length = 0.62"
(15.8)
+ thickness of mounting panel.
1.3"
(33)
Centerline of Ethernet port.