C
ONFIGURATION
D
ATA
F
ORMAT
Networked Indexer/Driver User Manual
ADVANCED MICRO CONTROLS INC.
60
CFG_Word_1 Format
Figure R6.2 Configuration Mode: Config Word Format
Bit 15: Reserved –
State ignored.
Bit 14: OUT1_Function –
“0” configures Output 1 to be a Fault Output. The output will conduct current
until a fault occurs. “1” configures Output 1 to be a general purpose output whose state is determined
by a bit in the Command Mode Network Output Data. This output is in an ON state when power is
applied to the Networked Driver and it has not yet been configured.
Bit 13: OUT1_Action_on_Connection_Lost –
This bit is only acted upon if Output 1 is configured as a
general purpose output. (Bit 14 above set to “1”.) A “0” on this bit will keep Output 1 at its last
value if the network connection is lost. A “1” on this bit will set the state of Output 1 to the value
specified in Bit 12 of this word.
Bit 12: OUT1_State_at_Connection_Lost –
This bit is only acted upon if Output 1 is configured as a gen-
eral purpose output. (Bit 14 above set to “1”.) When bit 13 of this word is set, Output 1 will be set to
the state of this bit if the network connection is lost.
Bits 11 - 7: Reserved –
Must equal zero.
Bit 6:
DC_Sync –
When set to “0”, the Networked Driver begins a move as soon as data is read from the
EtherCAT Slave Controller (ESC). When set to “1”, the Networked Driver will synchronize the move
to the SYNC0 output of the system’s Distributed Clock. This allows you to synchronize moves over
multiple devices.
Bits 5 - 3: Reserved –
Must equal zero.
Bit 2:
IN3_Active_Level –
Determines the active state of Input 3. Set to “0” if your sensor has Normally
Closed (NC) contacts and the input is active when there is no current flow through it. Set to “1” if
your sensor has Normally Open (NO) contacts and current flows through the input when it is active.
Bit 1:
IN2_Active_Level –
Determines the active state of Input 2. Set to “0” if your sensor has Normally
Closed (NC) contacts and the input is active when there is no current flow through it. Set to “1” if
your sensor has Normally Open (NO) contacts and current flows through the input when it is active.
Bit 0:
IN1_Active_Level –
Determines the active state of Input 1. Set to “0” if your sensor has Normally
Closed (NC) contacts and the input is active when there is no current flow through it. Set to “1” if
your sensor has Normally Open (NO) contacts and current flows through the input when it is active.
If you are not using an input, sets its Active_Level bit to “1”. The input will always report as
inactive in the network data.
The AMCI Networked Driver does not report the state of the inputs when they are configured
as encoder inputs (AB). The driver reports the state of the
Active Level Bit
for the input.
Configuration Word 1
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
OU
T1
Fn
OU
T1
AO
C
L
OU
T1
SA
C
L
0/
1
IGNORED: Bit can equal either value.
RESERVED: Bit must equal zero.
Содержание SD17060E-K
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S301...
Страница 20: ...UL CUL RECOGNIZED INSTALLATIONS Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 20 Notes...
Страница 40: ...MOTION CONTROL Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 40 Notes...
Страница 50: ...CALCULATING MOVE PROFILES Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 50 Notes...
Страница 56: ...HOMING AN AMCI NETWORKED DRIVER Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 56 Notes...
Страница 64: ...CONFIGURATION DATA FORMAT Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 64 Notes...
Страница 84: ...COMMAND MODE DATA FORMAT Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 84 Notes...
Страница 110: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...