20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
Input Data Format
6
85
Data Attribute 17: Counter Value Data
Figure 6.12 Counter Data Format (Data Attribute 17)
EtherNet/IP
Address
Modbus
Address
Bit Number
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
Ackno
wled
ge
Heartbeat
Ha
rd
wa
re
Fa
ult
Resolver Fault
Program Fault
Bits
RPM Clamped
Output Forced
0
1
0
0
0
1
1
1
Machine Position
2
2
Cycles of Active Program
32 bit integer. Lower 16 bits in word 3
3
3
4
4
Count Value of Batch Counter 1
32 bit integer. Lower 16 bits in word 3
5
5
6
6
Count Value of Batch Counter 2
32 bit integer. Lower 16 bits in word 3
7
7
8
8
Count Value of Batch Counter 3
32 bit integer. Lower 16 bits in word 3
9
9
10
10
Count Value of Revolutions Counter
32 bit integer. Lower 16 bits in word 3
11
11
12
12
Count Value of Good Parts Counter
32 bit integer. Lower 16 bits in word 3
13
13
14
14
Counter Overrun Assignment
(Bit 0 = Input 1 ... Bit 15 = Input 16)
These bits are normally ‘0’. A bit is set to ‘1’ if the output is
programmed to be a counter overflow output.
15
15
Program Cycle Overflow
(Bit 0 = Input 1 ... Bit 15 = Input 16)
These bits are normally ‘0’. A bit is set to ‘1’ if the output is assigned
to the Program Cycle counter and the counter is in its overflow state.
16
16
Batch Counter 1 Overflow
(Bit 0 = Input 1 ... Bit 15 = Input 16)
These bits are normally ‘0’. A bit is set to ‘1’ if the output is assigned
to the Batch Counter 1 and the counter is in its overflow state.
17
17
Batch Counter 2 Overflow
(Bit 0 = Input 1 ... Bit 15 = Input 16)
These bits are normally ‘0’. A bit is set to ‘1’ if the output is assigned
to the Batch Counter 2 and the counter is in its overflow state.
18
18
Batch Counter 3 Overflow
(Bit 0 = Input 1 ... Bit 15 = Input 16)
These bits are normally ‘0’. A bit is set to ‘1’ if the output is assigned
to the Batch Counter 3 and the counter is in its overflow state.
19
19
Not Used
Содержание ANS1 ANYNET-I/O
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0A090...
Страница 6: ...Table of Contents ADVANCED MICRO CONTROLS INC 6 Notes...
Страница 26: ...Limit Switch Functionality ADVANCED MICRO CONTROLS INC 2 26 Notes...
Страница 36: ...Additional Functionality ADVANCED MICRO CONTROLS INC 3 36 Notes...
Страница 90: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...