1022M

 

 

 

AMC-1022M SERIES 

HAZARDOUS GAS MONITORING 

SYSTEM INSTRUCTION MANUAL

 

 

 
 
 
 
 
 
 

Содержание 1022M Series

Страница 1: ...RATION OF THIS EQUIPMENT Revised 01 27 2000 Filename Manual_amc 1022M Copyright September 1989 The Armstrong Monitoring Corporation 613 225 9531 613 225 6965 Fax 800 465 5777 U S Toll Free www armstro...

Страница 2: ......

Страница 3: ...nside power relay panel 5 2 INSTALLATION 6 2 1 LOCATION AND MOUNTING 6 2 2 WIRING OF THE MONITOR SENSORS AND OR TRANSMITTERS 6 Figure 2 1 Monitor power supply connections 7 2 3 SCHEDULE OF CABLE SIZES...

Страница 4: ...iability arising from auxiliary interfaced equipment consequential damage or the installation and operation of this equipment Armstrong s total liability is contained in the warranty conditions stipul...

Страница 5: ...AG ___ Amp Operating Temperature Range 0 C to 40 C Sensors Transmitters Alarm Trip Points Chan No Part No Serial No Type of Gas Low High 1 2 3 4 5 6 7 8 9 10 11 12 NOTE ALL ARMSTRONG MONITORING SYSTEM...

Страница 6: ...erational see item 14 the buzzer will activate when a high alarm condition occurs 4 CLAMPS To secure the front panel restricting access to internal controls 5 POWER TERMINAL BLOCK For line voltage con...

Страница 7: ...omentary exposure to high levels of gas MIDDLE ACTUATOR Provides a FIVE minute time delay when switch is ON to eliminate unnecessary alarms caused by momentary exposure to low levels of gas RIGHT ACTU...

Страница 8: ...AMC AMC AMC AMC 1022M 1022M 1022M 1022M 3 FIGURE 1 2 AMC 1022M SERIES MONITOR FRONT PANEL...

Страница 9: ...AMC AMC AMC AMC 1022M 1022M 1022M 1022M 4 FIGURE 1 3 AMC 1022M SERIES MONITOR INSIDE FRONT PANEL...

Страница 10: ...AMC AMC AMC AMC 1022M 1022M 1022M 1022M 5 FIGURE 1 4 AMC 1022M SERIES MONITOR INSIDE POWER RELAY PANEL...

Страница 11: ...SMITTERS Power Supply The monitor operates on 120 VAC 60 HZ For each channel a class II step down transformer runs the internal circuitry at low voltages The power supply connections are made at the p...

Страница 12: ...listing of maximum distances the sensors or transmitters may be located from the monitor for various cable sizes CABLE LENGTH in FEET metres WIRE GAUGE AWG Remote Sensor or 3 Wire Transmitter 2 Wire...

Страница 13: ...AMC AMC AMC AMC 1022M 1022M 1022M 1022M 8 FIGURE 2 2 MONITOR MOUNTING DIMENSIONS...

Страница 14: ...AMC AMC AMC AMC 1022M 1022M 1022M 1022M 9 FIGURE 2 3 REMOTE SENSOR TRANSMITTER WIRING LAYOUT ONE CHANNEL...

Страница 15: ...AMC AMC AMC AMC 1022M 1022M 1022M 1022M 10 FIGURE 2 4 RELAY CONTACT ARRANGEMENT...

Страница 16: ...th remote sensor and or transmitter assemblies on site adjustments for remote sensors are made at the monitor and adjustments for transmitters are made at the transmitter locations The AMC l022M serie...

Страница 17: ...g the sensor being calibrated to the high alarm gas concentration and adjusting the HI trimmer clockwise until the red LED just lights NOTE IF A SENSOR HAS BEEN REPLACED ADJUST THE SIGNAL FIRST AND TH...

Страница 18: ...AMC AMC AMC AMC 1022M 1022M 1022M 1022M 13 FIGURE 3 1 TRIMMER ADJUSTMENTS AND TEST POINT LOCATIONS...

Страница 19: ...o gas This test should be performed regularly every 3 months but for more demanding applications verification should be performed on a weekly basis 4 3 SENSOR REPLACEMENT CAUTION TURN OFF POWER SUPPLY...