background image

9

4.  miniVES settings

 

» Change the generic name of the Audio input no. 3 to Local Audio IN

 

» In the Events Configuration tab assign the following events to Logical inputs:

Input 1: Active –select Audio Source – Local Audio IN(start), Inactive – select Audio 
Source – Local Audio IN (stop)

Input 2: Active –select zone – Zone 1 (start), Inactive – select zone – Zone 1 (stop)

Input 3: Active –select zone – Zone 2 (start), Inactive – select zone – Zone 2 (stop)

Input 4: Active –select zone – Zone 3 (start), Inactive – select zone – Zone 3 (stop)

Input 5: Active –select zone – Zone 4 (start), Inactive – select zone – Zone 4 (stop)

Содержание ABT-M04

Страница 1: ...User Manual EN Microphone ABT M04 www ambientsystem eu ver 04 2020 ...

Страница 2: ...______________________________________________________________________________ 7 3 Connection diagram____________________________________________________________________ 8 4 miniVES settings________________________________________________________________________ 9 5 Technical data_________________________________________________________________________ 10 ...

Страница 3: ...perating instructions should be adhered to 4 Follow all instructions All instructions for installation or use operating should be followed 5 Do no use this apparatus near water Do not use this apparatus near water or a moist environment for example near a bath tub wash bowl kitchen sink or laundry tub in a wet basement near a swimming pool in an unprotected outdoor installation or any area which i...

Страница 4: ...iance and cart combination to overturn 14 Unplug this apparatus during lighting storms or when unused for long periods of time Not applicable when special functions are to be maintained such as evacuation systems 15 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spi...

Страница 5: ...r system should not be located in the vicinity of overhead power lines or other electric light or power circuits or where it can fall into such power lines or circuits When installing an outdoor system extreme care should be taken to keep from touching such power lines or circuits as contact with them might be fatal Danger Object and Liquid entry never push objects of any kind into this apparatus ...

Страница 6: ...sconnect device is the mains plug of the power cord set If an AC DC adapter is provided and the mains plug that is part of the direct plug in device the AC DC adapter is the disconnect device The socket outlet shall be near the apparatus and shall be easily accessible Old electrical and electronic appliances Electrical or electronic devices that are no longer serviceable must be collected separate...

Страница 7: ...tus LED will switch from red not ready for broadcast to steady green light In the event of an active built in gong the status LED will turn green once the gong has ended When finished transmitting the message release the MIC ON button to deactivate the gooseneck mic Fig 1 ABT M04 main control placement 1 MIC ON button 2 Dynamic goose neck microphone 3 Zone selector 4 Gong volume knob 5 Gong ON OFF...

Страница 8: ...ophone Connector pinout Fig 3 BUS1 BUS2 IN7 IN6 IN5 IN4 IN3 IN2 IN1 48VDCBATT AudioIN AudioOUT C L R C L R 24VDC 150mA 48VDC 350mA TEMP SENSOR LINEA LINEB LINEC LINED HV AUDIOIN C H C H C H C H C H LINEA LINEB LINEC LINED HV AUDIOIN C H C H C H C H C H LAN WAN RS485 LAN LAN PoE IN1 IN2 B A FIBER 2 1 OUT3 OUT2 OUT1 1 2 3 4 6 7 8 5 PTT GND OUT POWER Z4 Z3 Z2 Z1 miniVES 4001LN Connecting the ABT M04 ...

Страница 9: ...select Audio Source Local Audio IN start Inactive select Audio Source Local Audio IN stop Input 2 Active select zone Zone 1 start Inactive select zone Zone 1 stop Input 3 Active select zone Zone 2 start Inactive select zone Zone 2 stop Input 4 Active select zone Zone 3 start Inactive select zone Zone 3 stop Input 5 Active select zone Zone 4 start Inactive select zone Zone 4 stop ...

Страница 10: ...l ABT M04 Operating voltage 20 57 VDC Efficiency 10 mV Pa Output level 775 mV Maximum distance from amplifier 250 m Recommended cable type UTP Connector Type 8P8C RJ45 Dimensions without packaging not more than 150 60 165 mm Net weight not more than 1 2 kg ...

Страница 11: ...11 ...

Страница 12: ...www ambientsystem eu Ambient System Sp z o o ul Bysewska 27 80 298 Gdańsk Poland T 48 58 345 51 95 ambient ambientsystem eu ...

Отзывы: