4.

 

Hygrometer (Humidity Meter) 

4.1

 

How the hygrometer works 

The  hygrometer  measures  the  indoor  relative  humidity.    The  sensor  measures  the air  moisture  by  a 
sensitive mechanical coil spring that is bonded with a moisture absorbent material. 
 
Hygrometers  register  the  percentage  of  water  vapor  present  in  the  air,  compared  to  the  maximum 
amount that can be present at a given temperature. 
 
The  coils  in  hygrometers  respond  slowly  and  while  humidity  levels  change  abruptly,  it  can  take  an 
hour  or  more  for  the  meter  to  reach  an  accurate  reading.  Remember  that  the  hygrometer  is  reading 
indoor  humidity,  and  is  vastly  different  than  outdoor  humidity,  as  reported  by  the  National  Weather 
Service. 
 
It is not uncommon to have low humidity reading during cold weather when indoor air is heater. Air 
conditioning  also  removes  moisture  from  the  air.    The  optimum  levels  are  45%  to  50%  during 
heating  and  cooling  seasons.    Low  humidity  can  cause  health  problems  and  can  be  hard  on  wood 
furnishings. High humidity can cause mold or mildew to grow. 

4.2

 

Hygrometer Accuracy 

 
Humidity  measurement  is  among  the  more  difficult  problems  in  basic  meteorology.  Accuracy  is 
difficult to achieve and are subject to drift, so need regular recalibration.   
 
A further difficulty is that  most hygrometers sense relative humidity rather than the absolute amount 
of water present, but relative humidity is a function of both temperature and absolute moisture content, 
so  small  temperature  variations  within  the  air  in  a  test  chamber  will  translate  into  relative  humidity 
variations. 

5.

 

Aneroid Barometer 

5.1

 

How the aneroid barometer works 

An  aneroid  barometer  uses  a  small,  flexible  metal  box  called  an  aneroid  cell.  This  aneroid  capsule 
(cell)  is  made  from  an  alloy  of  beryllium  and  copper.  The  evacuated  capsule  (or  usually  more 
capsules) is prevented from collapsing by a strong spring. Small changes in external air pressure cause 
the cell to expand or contract. This expansion and contraction drives mechanical levers such that the 
tiny movements of the capsule are amplified and displayed on the face of the aneroid barometer. Many 
models include a manually set needle which is used to mark the current measurement so a change can 
be seen. It was invented by Blaise Pascal. 

5.2

 

Reading the barometer 

It is highly advisable to lightly tap the glass near the center brass knob with your fingers before taking 
a barometer reading.    The light tap will overcome any friction that may affect accurate hand readings, 
especially during periods of slow atmospheric changes. The Coast Guard has informed us that tapping 
the barometer is even required on the most expensive aneroid barometers, because the mechanism is 
made deliberately “stiff”. 
 
The ability if the barometer to indicate changes in barometric pressure makes it a useful instrument in 
weather forecasting. 