background image

 

Version 1.0  

 

©Copyright 2017, Ambient LLC. All Rights Reserved. 

 

 

 

Page 4 

 

Figure 2 

 

3.

 

Channel Number:

 The sensor supports up to eight transmitters. To set each channel number 

(the default is Channel 1), change Dip Switches 1, 2 and 3, as referenced in Table 1. 

4.

 

Temperature Units of Measure:

 To change the transmitter display units of measure (°F vs. 

°C), change Dip Switch 4, as referenced in Table 1. 

 

DIP SWITCH

 

FUNCTION

 

1

 

2

 

3

 

4

 

DOWN 

DOWN 

DOWN 

--- 

Channel 1 

DOWN 

DOWN 

UP 

--- 

Channel 2 

DOWN 

UP 

DOWN 

--- 

Channel 3 

DOWN 

UP 

UP 

--- 

Channel 4 

UP 

DOWN 

DOWN 

--- 

Channel 5 

UP 

DOWN 

UP 

--- 

Channel 6 

UP 

UP 

DOWN 

--- 

Channel 7 

UP 

UP 

UP 

--- 

Channel 8 

--- 

--- 

--- 

DOWN 

°F 

--- 

--- 

--- 

UP 

°C 

 

Table 1 

5.

 

Insert two AAA batteries. 

6.

 

After  inserting  the  batteries,  the  remote  sensor  LED  indicator  will  light  for  4  seconds,  and 
then flash once per 60 seconds thereafter. Each time it flashes, the sensor is transmitting data. 

7.

 

Verify the correct channel number (CH) and temperature units of measure (°F vs. °C) are on 
the display, as shown in Figure 3. 

Содержание WS-0802

Страница 1: ...Defaults 8 5 1 4 Setting the Min and Max Alarm 9 5 2 Backlight Operation 9 5 3 Manually Reset Max Min 9 5 4 Channel Selection 9 5 5 Sensor Transmission 9 5 5 1 Sensor Search Mode 9 5 5 2 Best Practices for Wireless Communication 10 5 6 Adjustment or Calibration 10 5 6 1 Remote Sensor Temperature Calibration 11 5 6 2 Indoor Console Temperature Calibration 11 6 Glossary of Terms 12 7 Specifications ...

Страница 2: ...sold separately Item Number Image Description F007T 8 channel sensor measures temperature Applications include indoor and outdoor air temperature measurement F007TP 8 channel sensor measures probe temperature Applications include refrigerators and freezers where the probe is placed inside the appliance s and the display is outside water temperature soil temperature and ground temperature F007PF 8 ...

Страница 3: ...nsole Frame Dimensions LxHxW 4 77 x 2 95 x 0 6 in LCD Dimensions LxW 3 00 x 1 17 LCD Segment Height 0 70 inches 1 User Manual 2 2 Thermometer Sensor Set Up Note Do not use rechargeable batteries We recommend fresh alkaline batteries for temperature ranges between 4 F and 140 F and fresh lithium batteries for temperature ranges between 40 F and 140 F 1 Remove the battery door on the back of the sen...

Страница 4: ...in Table 1 DIP SWITCH FUNCTION 1 2 3 4 DOWN DOWN DOWN Channel 1 DOWN DOWN UP Channel 2 DOWN UP DOWN Channel 3 DOWN UP UP Channel 4 UP DOWN DOWN Channel 5 UP DOWN UP Channel 6 UP UP DOWN Channel 7 UP UP UP Channel 8 DOWN F UP C Table 1 5 Insert two AAA batteries 6 After inserting the batteries the remote sensor LED indicator will light for 4 seconds and then flash once per 60 seconds thereafter Eac...

Страница 5: ...o closing the door Tighten the set screw 3 Remote Sensor Installation It is recommended you mount the remote sensor on a north facing wall in a shaded area Direct sunlight and radiant heat sources will result in inaccurate temperature readings Although the sensor is water resistant it is best to mount in a well protected area such as under an eve Use a screw or nail not included to affix the remot...

Страница 6: ...ble unless fully charged and high quality batteries in the back of the display console All of the LCD segments will light up for a few seconds to verify all segments are operating properly 1 Replace the battery door and place the console in the upright position with the desk stand folded out The console will instantly display time and indoor temperature as designated The remote temperature will up...

Страница 7: ...cally switch to the normal mode and all further settings can be performed If the remote does not update please reference the troubleshooting guide in Section 8 4 1 Display Console Layout Figure 6 4 2 Sensor Operation Verification Verify the indoor and outdoor temperature match closely in the same location about 5 to 10 apart The sensors should be within 2 F the accuracy is 1 F Allow about 30 minut...

Страница 8: ...The time alarm icon will appear when set and disappear when disabled SET Alarm Minute Press the or key to increase or decrease the alarm minute While the alarm value is flashing press and hold the SET button for three seconds to toggle the alarm on and the alarm off The time alarm icon will appear when set and disappear when disabled SET Temperature Units of Measure Press the key to switch between...

Страница 9: ...on to decrease the LOW alarm Press and hold the or button to change rapidly While the alarm value is flashing press and hold the SET button for three seconds to toggle the alarm on and off the alarm The alarm icon will appear when set and disappear when disabled 5 2 Backlight Operation To temporarily turn on the back light for five seconds press the any button on the indoor sensor 5 3 Manually Res...

Страница 10: ...ry turning off these other devices for troubleshooting purposes You may need to relocate the transmitters or receivers to avoid intermittent communication 3 Line of Sight Rating This device is rated at 300 feet line of sight no interference barriers or walls but typically you will get 100 feet maximum under most real world installations which include passing through barriers or walls 4 Metal Barri...

Страница 11: ... 6 2 Indoor Console Temperature Calibration To enter the indoor temperature calibration mode press and hold the SET and MIN MAX buttons at the same time for 5 seconds and the INDOOR temperature value will begin flashing Press the CH button to increase the temperature and the MIN MAX button to decrease the temperature reading in 0 1 increments To rapidly increase or decrease the temperature reading...

Страница 12: ...7 2 Measurement Specifications The following table provides specifications for the measured parameters Measurement Range Accuracy Resolution Indoor Temperature 32 to 140 F 2 F 0 1 F Channel 1 8 Temperature 40 to 140 F 2 F 0 1 F 7 3 Power Consumption Base station display console 2 x AAA 1 5V Alkaline or Lithium batteries not included 2 x AAA 1 5V Alkaline or Lithium batteries not included Battery l...

Страница 13: ...range is 300 and 100 under most conditions Move the sensor assembly closer to the display console If the sensor assembly is too close less than 5 move the sensor assembly away from the display console Make sure the remote sensor LCD display is working and the transmitter light is flashing once per 60 seconds Install a fresh set of batteries in the remote thermo hygrometer For cold weather environm...

Страница 14: ...tions This product is not to be used for medical purposes or for public information The specifications of this product may change without prior notice This product is not a toy Keep out of the reach of children No part of this manual may be reproduced without written authorization of the manufacturer Ambient LLC WILL NOT ASSUME LIABILITY FOR INCIDENTAL CONSEQUENTIAL PUNITIVE OR OTHER SIMILAR DAMAG...

Страница 15: ...purchaser of this product To receive warranty service the purchaser must contact Ambient LLC for problem determination and service procedures Warranty service can only be performed by a Ambient LLC The original dated bill of sale must be presented upon request as proof of purchase to Ambient LLC Your Ambient LLC warranty covers all defects in material and workmanship with the following specified e...

Отзывы: