background image

RTSC

Thermostatic Flame Height Adjustment

Remote for

Signature Command System

INSTALLATION AND OPERATING

INSTRUCTIONS

This remote control system provides a safe, reliable and user-
friendly remote control for Signature Command equipped appli-
ances, and flame height adjustment. The system can be manually
or thermostatically turned on and off with the transmitter. Always
check the appliance home owner’s manual for additional informa-
tion, or warnings regarding accessory installation before connect-
ing this remote control system.

Carefully inspect the contents for shipping damage. If any parts
are missing or damaged, immediately contact the dealer from
whom you purchased the kit or Ambient Technologies Technical
Support at 1 800 398 6195. Do not attempt to install any part of
the kit unless all parts are in good condition. Please keep this
booklet for future reference.

CONTENTS OF KIT

Description

Qty

Transmitter

1

Battery Alkaline AAA (for Transmitter)

3

Installation Instructions

1

FEATURES/SPECIFICATIONS

• Thermostatic Control
• Battery Powered
• Low battery Indication
• Three Flame Height Setting
• Child Proof Lock-out
• 16 Security Codes
• Reset Button

WARNING

Important Safety Information

• Read this manual thoroughly prior to installing, programming or

operating any remote control.

• This remote control requires three (3) “AAA” alkaline batteries

to operate.

• This remote control system should only be used as described in

this manual. Any other use is not recommended and will void
the warranty.

Due to the sensitive temperature monitoring
components in the transmitter, it is necessary to
allow the transmitter to stabilize to room tem-
perature before accurate room temperatures are
displayed. If the transmitter is activated from a
severe cold condition, allow 15 minutes for accu-
rate temperature readings to appear on the LCD
display.

Turn appliance OFF (at the Master Switch) if
you are away from your house for an extended
period of time. Never leave anything on top of
the surface of the transmitter.

INSTALLATIONS

Installing Batteries

The remote transmitter uses three (3) “AAA” batteries.
To install batteries,

1. Press down the battery door tab

and pull out to remove the bat-
tery door.

2. Install the batteries as indicated

on transmitter.

3. Close the battery door by snap-

ping in place.

4. When three batteries are

installed, the transmitter will ini-
tialize for 10 seconds and then is
ready for use.

5. The batteries should be replaced

at least once every 6 months or
when the low battery icon indi-
cator is displayed.

Setting Privacy (DIP) Switch on Transmitter and the Learn

Function:

The remote transmitter privacy (DIP) switches are preset at the
factory. In the event of activation or interference from other near-
by transmissions, reset the code using the following procedures
(learn function must be performed after changing the code):

1. Slide the code switches on the transmitter to your choice of

ON or OFF position. Switches #1, #2, #3 and #4 are preset
to “ON” for the transmitter.

2. The RF receiver button on the control board must be in the on

position before the learn function can begin. Use paper clip to
depress button, one beep for RF receiver ON or two beeps for
RF receiver OFF.

3. Holding the OFF button on the Command Center while turning

on the master switch will activate the learn function for the

transmitter.

4. After the above operation, two beeps will be given and the

green LED on the Command Center will flash for 10 seconds.

5. During the 10 seconds, press the OFF button on a transmitter

to learn. Another two beeps will be given to confirm a success-
ful learning.

Do not use two (2) or more remote control sys-
tems in the same area with the same dip switch
settings, as they will communicate with each
other. This may cause the appliances to mal-
function.

Reset Button:

The reset button can be used to reset the transmitter if transmitter

is not working properly. The reset button is located behind the
battery door cover in the lower left corner of battery comparment.
Using a paper clip, press the reset button and the transmitter will
reset and initialize for 10 seconds before it can be used.

OPERATIONS

Transmitter

General

The RTSC Remote Control has two (2)
operating modes: Manual and Thermostatic.
The control system can be set to tempera-
ture ranges between 45°F and 90°F. The
flame height can be adjusted in either the
manual and thermostatic mode.

The transmitter will operate the remote
receiver from 1foot to a maximum of 30
feet. The distance is reduced when batteries
are low.

Initial Start-up

1. After initial power up or when

RESET button is pressed, the trans-
mitter is reset. The reset button is
located behind the battery door of
transmitter.

2. During system reset, all features of

the LCD DISPLAY will be visible.
After one second, the LCD will be
initialized. A typical reset display is
shown above. Note that the temper-
ature scale is degree F.

3. Press On button to select between °C and °F display. It

will exit setting mode automatically after 10 seconds if no
key is pressed. The transmitter will send an Off signal
after reset.

4. After reset, the transmitter is operating in manual mode.

The room temperature is shown as above.

Manual Mode:

1. Press the ON button once to turn on

the appliance with max flame
height.

2. Press the OFF button to decrease

flame height. The first two pressing
will decrease flame height to lower
level. The third pressing will turn
fireplace off.

3. At any time holding the OFF button

for more than 3 second, fireplace will be shut off and
remember the last setting.

Thermostatic Mode:

1. Press the AUTO button to enter the

thermostatic mode.

2. In thermostatic mode, press the ON

/

button or OFF /

button to set

the desired set temperature.

3. Once the setting is completed, the

transmitter will automatically turn
on the fireplace when the room
temperature is below the set tem-
perature and turn off the appliance
when the room temperature is
above the set temperature within 1 degree.

4. There will be a slight delay in the response of the unit

(on/off) to a temperature. Room temperature is monitored
every 3 minutes.

5. Press the Auto button to exit the thermostatic mode. The

transmitter will be in the manual off mode and the fireplace
will be shut off.

Flame Height Setting for Thermostatic Mode:

1. Hold AUTO button for 5 seconds

and one number and flame icon
will show up in LCD screen, as
shown in the right figure.

2. Use the ON /

or OFF /

button

to set the desired flame height to 1
(Min), 2 (Medium) and 3 (Max)

3. If there is no input within 3 sec-

onds, the new setting will be trans-
mitted to receiver. This setting

W

A

R

N

IN

G

Back of the Transmitter

Battery

Door

Tab

N

O

T

E

Dip Switch (Default)

Control Board & Command Center

Transmitter

W

A

R

N

IN

G

RTSC manual v2:RTSC manual v2

10/31/08

11:20 AM

Page 1

f i r e - p a r t s . c o m

Отзывы: