23
Installation
13.3 Min/Max Vent Run
Instructions for installing venting and terminations (see list for approved venting and terminations).
Install the termination cap being sure to provide sufficient space (around and on top) so you do not impede the flow of air,
both into and out of the cap. This cap is only to be used for non combustible installations. Do not recess into the top of the
chimney.
1.
Mark each end of one flex liner with “
Air Intake
”.
2.
Mark each end of the second flex liner with “
Exhaust
”.
3.
Pull the liner through the chimney.
4.
Install the flashing.
5.
Seal and attach the flex liner marked “
Air Intake
” to the vent terminal pipe marked “
Air Intake
” as per terminal manufacturers
instruction.
DO NOT USE SILICONE.
6.
Seal and attach the flex liner marked “
Exhaust
” to the vent terminal pipe marked “
Exhaust
” as per terminal manufacturers
instruction.
DO NOT USE SILICONE.
7.
Seal and attach the end of the flex liner marked
“Air Intake”
to the collar marked “
Air Intake
” on the appliance with the collar
clamp provided with the unit.
DO NOT USE SILICONE.
8.
Seal and attach the end of the flex liner marked “
Exhaust
” to the collar marked “
Exhaust
” on the appliance with the collar clamp
provided with the unit.
DO NOT USE SILICONE.
9.
Caulk all joints using a high temperature sealant such as milpac.
DO NOT USE SILICONE. Use of silicone sealants voids the
warranty of the pilot assembly
.
NOTE:
The flex liners must form a complete connection from the appliance flue collars to the vertical termination cap.
The minimum flue (chimney) size required to run the two 3" (76 mm) is 4" x 7" (100 mm x 178 mm).
Figure 13.3.01: