![Amazone ZA-M Profis Hydro Скачать руководство пользователя страница 96](http://html1.mh-extra.com/html/amazone/za-m-profis-hydro/za-m-profis-hydro_operating-manual_2919788096.webp)
Cleaning, maintenance and repairs
96
ZA-M BAG0040.8 09.15
12.8
Adjusting the clearance at the check screws
The check screws (Fig. 56/2) must be set with 2
mm clearance as shown.
They are located to the left and right of the
spreader frame.
For this purpose:
1. Release the lock nut (Fig. 56/1)
2. Adjust the check screws (Fig. 56/2)
3. Tighten the lock nut (Fig. 56/1)
Fig. 56
Adjustment must be made with the
spreader empty.
12.9
Taring the spreader
If the control terminal does not show 0 kg (+/- 5 kg) fill weight with the
spreader empty, the spreader must be retared (See operating manual
for software AMABUS).
This may occur, for example, after the attachment of special accesso-
ries.
12.10
Calibrating the spreader
If after filling the retared spreader does not show the correct fill
weight, the spreader must be recalibrated (See operating manual for
software AMABUS).