Using the machine
10.9.1
Cleaning the sprayer with the tank empty
•
Clean the spray liquid tank on a daily basis!
•
The flushing water tank must be filled completely.
•
The cleaning process should be carried out in a threefold reduc-
tion procedure.
1. Set the pump drive pumping speed
to 500 rpm.
No DUS pressure circulation system:
→
Step 6
Pressure circulation system (DUS):
2. DUS: Switch tap
A
in position
.
3. DUS: Switch tap
B
in position
.
4. Agitator
C
,open
G
completely to remove
deposits in the in the hose.
→
Flush the agitators with 10 % of the flushing
water supply.
5. Switch off the agitator(s).
Fig. 133
DUS: Spray lines are automatically
rinsed.
6. Switch tap
B
in position
.
→
Perform internal cleaning with 10 % of the
flushing water supply.
7. Switch tap
B
in position
.
8. Switch tap
A
in position
.
9. Spreads residues already diluted on the
treated area when driving.
10. Using the on-board computer, switch spray-
er on and off several times for several sec-
onds.
The valves and return lines are
flushed by switching on and off.
→
Keep flushing the diluted residues until air
escapes from the nozzles.
BAG0021.14 05.19
183
Содержание UG 2200 Special
Страница 237: ...Liquid circuit 13 1 UG Special BAG0021 14 05 19 237 ...
Страница 238: ...Liquid circuit 13 2 UG Super 238 BAG0021 14 05 19 ...
Страница 242: ...Spray table Fig 182 242 BAG0021 14 05 19 ...
Страница 251: ...Spray table BAG0021 14 05 19 251 ...
Страница 252: ......