Control terminal shows a spread rate error
1.
Remove the spring cotter pin
1
.
2.
Press the shot channel
2
down against the
spring element
3
.
3.
Remove the shot channel upwards.
4.
Clean the shot channel.
5.
Install the shot channel.
6.
Secure the shot channel with a spring cotter pin
1
.
2
1
3
CMS-I-00002040
Blocking of the press rollers
NOTE
Offset installation is not possible in conjunction
with disc closers.
1.
Unscrew the nut
1
and remove it.
2.
Remove the press roller.
3.
To increase the throughput on the press rollers,
install the press roller with offset.
4.
Install the press roller with the bolt
2
in the hole
3
.
5.
Put on the nut and tighten it.
1
2
3
CMS-I-00002041
CMS-T-00002348-B.1
CMS-T-00002373-B.1
8 | Eliminating faults
MG6659-EN-GB | F.1 | 25.10.2022 | © AMAZONE
130