5.
Check that all of the disc carriers are aligned
evenly.
6.
Tighten the lock nuts.
CMS-I-00003385
10.1.6 Checking the tine fastening with compression spring overload safety
INTERVAL
Every 50 operating hours
or
weekly
Check the bolted connections
1
for tight fit.
1
1
1
1
410 Nm
CMS-I-00004863
10.1.7 Replacing tines with compression spring overload safety
INTERVAL
as required
WARNING
Risk of crushing due to lowering of the
implement
Raise the implement only slightly.
CMS-T-00004207-B.1
CMS-T-00004187-B.1
10 | Repairing the implement
Maintaining the implement
MG7242-EN-GB | L.1 | 26.07.2022 | © AMAZONE