6.
Clean the metering unit protective screen
1
.
7.
Close the roller tarpaulin.
1
CMS-I-00006779
10.2.11 Cleaning the cyclone separator
INTERVAL
Every 10 operating hours
or
daily
For the cyclone separator to work, the separator
opening
3
must be free of impurities.
1.
Check the separator opening
3
.
2.
If the separator opening in clogged,
open the clips
2
.
3.
Loosen the wing nut
1
.
4.
Remove the cover and clean it.
5.
Install the cover with the wing nut.
6.
Fasten the suction cage with the clips.
1
2
3
CMS-I-00002765
CMS-T-00003779-C.1
10 | Repairing the implement
Maintaining the implement
MG7508-EN-GB | B.1 | 31.08.2022 | © AMAZONE
128