![Amazone Catros 4003-2TS Скачать руководство пользователя страница 98](http://html1.mh-extra.com/html/amazone/catros-4003-2ts/catros-4003-2ts_original-operating-manual_2919720098.webp)
10.1.19 Checking the central lubrication
INTERVAL
daily
1.
If the fill level is low in the tank
1
,
fill in grease through the filling nipple
3
until just
below the "MAX" mark.
2.
If grease emerged on the pressure relief valve
2
,
see "Eliminating faults".
2
-MAX-
-MIN-
1
3
CMS-I-00004515
10.2 Cleaning the machine
IMPORTANT
Risk of machine damage due to cleaning
jet of the high-pressure nozzle
Never direct the cleaning jet of the
high-pressure cleaner or hot water
high-pressure cleaner onto the marked
components.
Never aim the cleaning jet of high-
pressure cleaners or hot water high-
pressure cleaners on electrical or
electronic components.
Never aim the cleaning jet of the high
pressure cleaner directly on lubrication
points, bearings, rating plates, warning
signs, and stickers.
Always maintain a minimum distance
of 300 mm between the high-pressure
nozzle and the machine.
Do not exceed a water pressure of 120
bar.
CMS-T-00006317-A.1
CMS-T-00000593-C.1
10 | Repairing the machine
Cleaning the machine
MG6828-EN-II | N.1 | 13.08.2021
92