Window-Mounted Air Conditioner with Remote, Energystar
Sistema de Aire Acondicionado para Instalación en Ventanas, con 

Control Remoto, Energystar
Climatiseur De Type Fenêtre avec Télécommande, Certifié Energystar
B07Y2CND3Q, B07Y2C57KD, B07Y2B3ZXV, B07N6LPL7V

Содержание B07N6LPL7V

Страница 1: ...oner with Remote Energystar Sistema de Aire Acondicionado para Instalaci n en Ventanas con Control Remoto Energystar Climatiseur De Type Fen tre avec T l commande Certifi Energystar B07Y2CND3Q B07Y2C5...

Страница 2: ...English 4 Espa o 37 Fran ais 69...

Страница 3: ...3 x 2 1 8 LEFT RIGHT A x 1 B x 1 C x 1 D x 1 E x 1 F x 1 G x 2 H x 2 I x 1 J x 1 K x 4 L x 7 M x 2 N x 2 AAA AAA 3 2 mm...

Страница 4: ...ierce or burn Be aware that refrigerants may not contain an odor Appliance shall be installed operated and stored in a room with a floor area larger than 120 ft2 11 m2 This appliance is not intended f...

Страница 5: ...g wall outlet to minimize the possibility of electric shock Where a 2 prong outlet is encountered it must be replaced with a properly grounded 3 prong wall outlet Always use dedicated power circuit wi...

Страница 6: ...cord must be connected to indoor power supply only This product is not intended for use in bathrooms laundry areas and similar indoor locations This product is intended for household use only It is no...

Страница 7: ...wn on the product rating label DANGER Risk of suffocation Keep any packaging materials away from children these materials are a potential source of danger e g suffocation Product Description Main unit...

Страница 8: ...r 17 Relay signal indicator 4 Timer off indicator 18 Sleep indicator 5 Clean filter button 19 Reset button 6 Mode indicator 20 Follow me button 7 Mode button 21 Lock button 8 Energy Saver button 22 LE...

Страница 9: ...roduct should be installed by 2 skilled persons To avoid vibration and noise make sure the product is installed securely and firmly The window should be able to withstand the weight of the product Ins...

Страница 10: ...acles might limit the heat radiation which greatly reduces the cooling efficiency of the product Install the product with its bottom portion approx 30 60 75 150 cm above the floor level Install the pr...

Страница 11: ...rdion shutter E out of the frame Slide the rail into the shutter locks T of the main unit Repeat on the other side with the left accordion shutter D Step 3 x2 E F Q Slide the top and bottom rails of t...

Страница 12: ...sure the product is tilted 3 to 4 A 0 75 1 1 9 2 cm downwards with reference to the window sill Step 5 E D Fully extend the accordion shutters E and D so they fit the window frame Not shown Use the st...

Страница 13: ...Secure the accordion shutters E and D with the brackets H and the screws L Step 7 D E L F 1 1 2 NOTICE Before securing the accordion shutters E and D and the top rail F mark and drill 3 pilot holes in...

Страница 14: ...k and drill 2 pilot holes to prevent it from splitting Secure the position of the lower window sash using the bracket I and 2 screws L Step 9 1 2 B Measure the width of the window sash Cut the sash se...

Страница 15: ...the sash seal B between the lower and upper window sash Step 11 x2 2 1 x Measure the widths between the isolation board intakes of the accordion shutters E and D Cut the isolation boards N according t...

Страница 16: ...and product If no damage is visible reset the product by pressing the RESET button N If the LCDI de activates again a hazardous condition may be present and the product should be discarded or returned...

Страница 17: ...de control To set the mode press the mode button 7 The active mode is indicated by the mode indicator 6 Icon control panel Icon remote control Description Auto Depending on the set target temperature...

Страница 18: ...ress the timer button 15 to initialize the timer setting Press the timer button 15 several times to toggle between the on timer and the off timer The chosen function is indicated by the timer indicato...

Страница 19: ...Energy saver NOTICE The energy saver control does not work in fan mode While the energy saver is activated the product is cooling the room with the maximum compressor efficiency below the set target t...

Страница 20: ...s to flash Set the time with the decrease 2 and increase 16 buttons Press and hold the button to change the time quicker Press the clock button 23 to confirm the setting F C Press and hold both the de...

Страница 21: ...factory settings press the reset button 19 e g with a toothpick Clean filter reminder The product measures the total working time After 250 hours of operation the indicator above the clean filter but...

Страница 22: ...vent control V to choose one of the below air circulation mode Position Description Vent Exhaust Vent closed The air circulates inside the room Closed Closed Half opened The fresh air is drawn into th...

Страница 23: ...at least every 2 weeks NOTICE Do not clean the filter with water warmer than 104 F 40 C Open the front grill U and remove the filter Pull out the filter on the right side Rinse the filter thoroughly i...

Страница 24: ...r of the electrical installation tripped Flip the suspect breaker to the on position The product does not cool efficiently Clean the removable air filter Check the air vents for obstructions Adjust th...

Страница 25: ...ture from the humid room The product does not respond to the remote control Operate the remote control within 26 ft 8 m from the product Point the remote control directly towards the product when oper...

Страница 26: ...ndesired operation 2 Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment FCC Interference Statement This eq...

Страница 27: ...x 983 6 W Rated current 4 5 A max 6 5 A 8 03 A max 9 68 A Standby power 0 9 W 1 W Fuse 15 A 15 A Cooling capacity 250 ft2 23 2 m2 6000 BTU h 450 ft2 52 m2 10000 BTU h Design pressure 300 520 PSI 20 7...

Страница 28: ...9 A max 8 4 A Standby power 1 W 0 9 W Fuse 15 A 10 A Cooling capacity 550 ft2 42 m2 12000 BTU h 118 172 ft2 11 16 m2 8000 BTU h Design pressure 300 520 PSI 20 7 35 9 bar 300 520 PSI 20 7 35 9 bar Indo...

Страница 29: ...on com review review your purchases amazon com gp help customer contact us END OF USER MANUAL SERVICING MANUAL Servicing Any person who is involved with working on or breaking into a refrigerant circu...

Страница 30: ...are of potentially flammable atmospheres Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants i e non sparking adequately sealed or intrinsically safe Pr...

Страница 31: ...ence of refrigerant Marking to the equipment continues to be visible and legible Markings and signs that are illegible shall be corrected Refrigeration pipe or components are installed in a position w...

Страница 32: ...NOTICE The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment Intrinsically safe components do not have to be isolated prior to working on them Repair to in...

Страница 33: ...l naked flames shall be removed extinguished If a leakage of refrigerant is found which requires brazing all of the refrigerant shall be recovered from the system or isolated by means of shut off valv...

Страница 34: ...e kept upright Ensure that the refrigeration system is earthed prior to charging the system with refrigerant Label the system when charging is complete if not already Extreme care shall be taken not t...

Страница 35: ...d off 11 Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked Labelling Equipment shall be labelled stating that it has been de commissio...

Страница 36: ...ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevan...

Страница 37: ...amazon com AmazonBasics V05 11 19 MADE IN CHINA FABRIQU EN CHINE HECHO EN CHINA...