![AMATI HY08 Series Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/amati/hy08-series/hy08-series_user-manual_2918831001.webp)
HY08 And HY311 Series Heating Thermostat User Manual
Many thanks for your selection of our products and services, and also for your trust and
support to us
.
HY08WE-1/HY08WW-1
HY08WE-4/HY08WW-4
HY08WE-2/HY08WW-2
HY08WE-3/HY08WW-3
Product Specifications
☆
Power: 90-240Vac 50/60HZ
☆
Range of temperature display:
:
0~40°C
☆
Display accuracy:
:
0.5°C
☆
Insulating condition: Normal environment
☆
Probe sensor:
:
NTC(10k)1%
☆
Running program: Set per 1 week as a cycle
☆
Contact capacity:
:
3A/250V(WW);16A/250V(WE)
☆
Output: Switch relay
☆
Working environment temperature:
:
0~90°C
☆
Installation: Wall mounted or on battery seat
☆
Range of temperature adjustment:
:
5~35°C
☆
Size(mm)
:
86*86*27
Before wiring and installing
1. Read these instructions carefully. Failure to follow them could damage the product or cause a
hazardous condition.
2. Check the ratings given in the instructions and on the product to make sure the produce is suitable
for your application.
3. Installer must be a trained experienced service technician.
4. After installation is complete.check out produce operation as provided in these instructions
CAUTION
Electrical shock or equipment Damage Hazard. or short equipment circuitry.
Disconnect power supply before installation
Wiring Diagram
Electric heating wiring diagram
Water heating wiring diagram
(do not connect terminal "close 4" of electric valve)
Water heating and gas wall-hung boiler heating,
no contact wiring diagram,(disconnection when electric valve close)
Note:3 & 4 connect with power, 5 & 6 connect with gas boiler,1& 2
connect with thermal actuator, please do not connect 1&2 to gas
boiler,If you connect it wrongly, there will be Short circuit,our gas boiler
board will be damaged.
Displays
Description of icon
Auto mode;run preset program
Manual mode
Clock
External NTC sensor
Holiday mode, Holiday days and temperature can be set to run in countdown mode
Heating,icon disappears to stop heating
Child lock
Cloud icon
Fault Warning
Operation key
NO
symbols
represent
A
Turn ON/OFF:Short press to turn on/ turn off
B
1 Short press
/
to switch automatic mode and manual mode
2 Turn on thermostat, long press
/
for 3-5 seconds to enter into programmable
setting
3. Turn off thermostat, long press
/
for 3-5 seconds to enter into advanced
setting
C
1 Confirm key: use it with
/
key
2 Only short press it to set time
3 Turn on thermostat,long press it for 3-5seconds to holiday mode setting. Appear