FPT-40 Fingerprint Terminal Installation & Operation Guide
Page 3-9
Replacing Optical Sensor Lens
To replace the optical sensor lens:
1. If optical sensor lens becomes damaged (scratched) and cannot be
cleaned, replacement may be necessary.
2. Use the replacement [spare] optical sensor lens included with the
terminal. Remove the spare sensor lens from the protective
packaging (see figure), using care not to touch the prism.
3-12
Spare Prism & Packaging
3. Disconnect the AC Power Adapter from the bottom of the terminal.
4. Disconnect the communication cable (either Ethernet or serial DB9
connector)
5. Loosen and remove the four (4) back plate retaining screws and
remove the terminal from the wall mounted back plate.
6. Place the terminal on a soft surface face down. Located and remove
the four (4) Phillips Head screws holding the case front cover. There
will be one screw in each corner on the back of the case.
7. After removing the screws, place the terminal right-side up on the
back of the case and VERY CAREFULLY lift the front cover up.
8. The sensor housing must be removed by unscrewing the four (4)
Phillips head screws holding it down to access the optical sensor
lens (see figure).
Prism
Содержание Time Guardian FRT-40
Страница 1: ...888 534 5994 FPT 40 USER MANUAL...
Страница 2: ...Time Guardian FPT 40 Fingerprint Data Collection Terminal Installation Operation Guide...
Страница 15: ...Page 1 10 FPT 40 Fingerprint Terminal Installation Operation Guide This page intentionally left blank...
Страница 67: ...Page 2 52 FPT 40 Fingerprint Terminal Installation Operation Guide This page intentionally left blank...
Страница 91: ...Page 4 14 FPT 40 Fingerprint Terminal Installation Operation Guide NOTES...
Страница 93: ...AMX 500001 10 08 00...