Appendix C: Configuration Reference
167
notify_restriction
If you specify a port, Amanda restricts notification to that port. However, the port still
takes incoming calls.
Use any port number or 0. 0, the default, means that roving or dedicated notification is
being used instead of restricted notification. You typically use the last port in the linear
hunt group.
You must use this option if you install Amanda on a telephone switching system that re-
quires the same port to turn message lights both on and off. In this case, roving notifi-
cation could cause a message light to come on and stay on.
Restricted notification does not eliminate the possibility of notification collisions
(known as glare).
If notify_restriction is set to an invalid value, Amanda detects that during startup, resets
notify_restriction to the highest port number, and logs that fact. See also n_ochan.
The default appears in install.cfg as:
set notify_restriction 0
off_dly
Amount of time after a line goes off-hook before the voice board notifies Amanda that
the line is off-hook.
Number of hundredths of seconds. The default is 50 (.5 sec.). The range is 1-6553. The
numbers 0 and -1 have special meanings.
When 0, Amanda uses the voice board's default (which is also 50).
When -1, there is no delay.
The default appears in install.cfg as:
set off_dly 50
partial_q_ok
Determines what messages are saved when the Q() command is used to get answers from
a caller.
True or False. The default is False.
When True, Amanda saves a message even if the caller hangs up before answering all
the questions.
When False, Amanda does
not
save a message using the Q() command unless all the
questions have been answered.
The default appears in install.cfg as:
set partial_q_ok false
password
Sets the Amanda password. The password is case-sensitive, so uppercase letters are dif-
ferent from lowercase letters. That means that AMandA, Amanda, and amanda all rep-
resent different passwords.
Use a text string with a maximum length is 8 characters. The default is AMandA.
If you use the null string (that is, no password), you must use a dealer password to oper-
ate and shut down Amanda.
The default appears in install.cfg as:
set password 'AMandA'
General Options (Continued)
Configuration Option
Description
Содержание [email protected] Version 3.xx
Страница 1: ...Installing AmAndA Work Place Version 3 xx Installer s Guide Edition 7 01...
Страница 4: ...iv Installing Amanda Work Place...
Страница 60: ...52 Installing Amanda Work Place...
Страница 68: ...60 Installing Amanda Work Place...
Страница 132: ...124 Installing Amanda Work Place...
Страница 150: ...142 Installing Amanda Work Place...
Страница 156: ...148 Installing Amanda Work Place...
Страница 194: ...186 Installing Amanda Work Place...
Страница 206: ...198Installing Amanda Work Place...