background image

®

Amana

Fayetteville, TN 37334

NOTE: It is important to electrically connect the unit and
properly size fuses/circuit breakers and wires in accor-
dance with all national and/or local electrical codes. Use
copper wire only.

Standard Features

• Bi-Flow Liquid Line Filter-Drier (Shipped Loose)
• Front Seating Valves
• Scroll Compressor
• 5 Minute Anti-Short Cycle Protection
• Automatic Reset High Pressure Switch
• Dual Defrost Sensors
• Automatic Reset Loss Of Charge Switch
• Adaptive Demand Defrost
• Spring Loaded Check Valves
• Eight Pole Motor

Accessories

• Fossil Fuel Kit (FFK02A)
• Compressor Sound Blanket (CSB08A)
• Ambient Temperature Kit (ATK05A)
• Hard Start Kit (HSK12A)
• Freeze Protection Kit (FSK01A)

(Installed On Indoor Coil)

NOTE: When mix matching with restrictor orifice indoor
coil, use restrictor orifice part number B1443819 or
11076315, 0.098 diameter.

Heat Pump Performance Data

For ARI Performance Data: See the ARI Directory, Product Data Booklet (PDB), or the product Service Manual.

March 2000

11070191

Above information is for nominal CFM and 70° F indoor dry bulb.

All pressures are PSIG.

All temperatures are °F.

RHE60A2A / BHA60TB002A

Outdoor Ambient Temperature (° F)

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

T

38

36

34

32

30

29

27

25

23

22

20

19

18

16

14

13

11

9

Amps

30.2 27.9 26.1 24.6 23.7 23.2 21.9 20.8 19.9 19.0 18.1 17.6 17.4 16.5 15.4 14.5 13.4 12.0

HI PR

296

284

273

261

255

250

240

231

221

211

203

198

194

187

180

172

166

160

LO PR

75

69

65

60

56

54

50

44

40

36

31

29

28

24

21

17

15

12

Specifications

Cooling Capacity, BTUH (Nominal)

59,500

Compressor

 

R.L. Amps

28.8

L.R. Amps

169.0

Condenser Fan Motor

Horsepower

1/3

R.L. Amps

2.3

L.R. Amps

3.6

Liquid Line, Inches O.D. 

3/8

Suction Line, Inches O.D. 

1 1/8

Refrigerant Charge (oz)

288

Power Supply

208/230-60-1

Min Circuit Ampacity

38.2

Max Overcurrent Device

60.0

Electric Conduit Size (in)

Power Supply

1/2 or 3/4

Low Voltage

1/2

Approximate Shipping Weight (Lbs)

345

RHE60A2A

Remote Heat Pump

Specification Sheet

Due to policy of continual product improvement,

the right is reserved to change specifications and

design without notice.