background image

Goodman Company, L.P.

1810 Wilson Parkway  •  Fayetteville, Tennessee  37334

www.amana-hac.com

C om fort. Quality. Tru st.

Heating

®

&

Air Conditioning

Part No.
Printed in USA

Standard Features

• Bi-Flow Liquid Line Filter Drier (Factory Installed)
• Back Seating Service Valves
• Scroll Compressor
• Manual Reset High Pressure Switch
• Automatic Reset Loss Of Charge Switch
• Time/Temperature Defrost
• Heating Mode Thermostatic Expansion Valve (TXV)

with Internal Check Valve

• Eight-Pole Condenser Fan Motor
• Compressor Sound Blanket

Accessories

• Fossil Fuel Kit (FFK03A)
• Hard Start Kit (HSK10A)
• Freeze Protection Kit (FSK01A)

(Installed On Indoor Coil)

• Anti Short Cycle Protection

Heat Pump Performance Data

For ARI Performance Data: See the ARI Directory, Product Data Booklet (PDB), or the product Service Manual.

Above information is for nominal CFM and 70° F indoor dry bulb.
All pressures are PSIG.
All temperatures are °F.

NOTE:

 It is important to electrically connect the unit and

properly size fuses/circuit breakers and wires in accor-
dance with all national and/or local electrical codes. Use
copper wire only.

S

PECIFICATION

 S

HEET

R

EMOTE

 H

EAT

 P

UMP

Due to policy of continual product

improvement, the right is reserved to

change specifications and design

without notice.

20451313 (1)

RHE48C2A

RHE48C2A  / CHA60TCC / BBC60A2A@TAP B

48,500

 

27.2

137

1/3
2.3
3.6
3/8
7/8

242

208/230-60-1

36.2
50.0

1/2 or 3/4

1/2

281

Low Voltage

Power Supply (volts)

Min. Circuit Ampacity
Max. Overcurrent Device (amps)

Electric Conduit Size (in.)

Liquid Line, Inches O.D. 
Suction Line, Inches O.D. 
Refrigerant Charge (oz.)

Power Supply

Specifications

Approximate Shipping Weight (lbs.)

Cooling Capacity, BTUH (Nominal)
Compressor

R.L. Amps
L.R. Amps

Condenser Fan Motor

Horsepower
R.L. Amps
L.R. Amps

Outdoor Ambient Temperature (° F)

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

T

34

32

30

28

27

26

24

22

20

19

17

16

16

14

13

11

9

8

Amps

20.6 19.1 17.9 16.9 16.3 16.0 15.1 14.4 13.8 13.2 12.6 12.3 12.2 11.6 10.9 10.3 9.5

8.6

HI PR

263 252 242 231 226 222 213 205 196 187 180 175 172 166 159 153 147 142

LO PR

73

68

64

59

55

53

49

44

39

35

31

29

28

23

20

17

15

12

When mix-matching with restrictor orifice

indoor coil, use Chatleff .092 diameter

restrictor orifice 11076314.