background image

®

Amana

Fayetteville, TN 37334

NOTE: It is important to electrically connect the unit
and properly size fuses/circuit breakers and wires in
accordance with all national and/or local electrical
codes. Use copper wire only.

Standard Features

• Bi-Flow Liquid Line Filter-Drier (Shipped Loose)
• Front Seating Valves
• Scroll Compressor
• 5 Minute Anti-Short Cycle Protection
• Automatic Reset High Pressure Switch
• Automatic Reset Loss Of Charge Switch
• Adaptive Demand Defrost
• Spring Loaded Check Valves
• Eight Pole Motor
• Dual Defrost Sensors

Accessories

• Fossil Fuel Kit (FFK03A)
• Compressor Sound Blanket (CSB08A)
• Ambient Temperature Kit (ATK05A)
• Hard Start Kit (HSK10A)
• Freeze Protector Kit (FSK01A)

(Installed on Indoor Coil)

NOTE: When mix matching with restrictor orifice indoor coil,
use restrictor orifice part number B1443808 or 11076306,
0.069 diameter.

Heat Pump Performance Data

For ARI Performance Data: See the ARI Directory, Product Data Booklet (PDB), or the product Service Manual.

August 1999

11070153

Above information is for nominal CFM and 70° F indoor dry bulb.

All pressures are PSIG.

All temperatures are °F.

Specifications

Cooling Capacity, BTUH (Nominal)

30,000

Compressor

 

R.L. Amps

13.5

L.R. Amps

72.5

Condenser Fan Motor

Horsepower

1/6

R.L. Amps

1.1

L.R. Amps

2.1

Liquid Line, Inches O.D. 

3/8

Suction Line, Inches O.D. 

3/4

Refrigerant Charge (oz)

189.5

Power Supply

208/230-60-1

Min Circuit Ampacity

18.1

Max Overcurrent Device

30.0

Electric Conduit Size (in)

Power Supply

1/2 or 3/4

Low Voltage

1/2

Approximate Shipping Weight (Lbs)

218

RHE30A2A / BHA30TB002A

Outdoor Ambient Temperature (° F)

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

T

33

31

29

27

26

25

23

22

20

18

17

16

15

14

12

11

9

7

Amps

13.6 12.6 11.8 11.1 10.7 10.5

9.9

9.4

9.0

8.6

8.2

8.0

7.9

7.5

7.0

6.6

6.1

5.5

HI PR

252

242

232

222

217

213

205

196

188

180

173

168

165

159

153

147

141

136

LO PR

76

70

66

60

57

55

50

45

41

36

32

30

29

24

21

18

15

12

RHE30A2A

Remote Heat Pump

Specification Sheet

Due to policy of continual product improvement,

the right is reserved to change specifications and

design without notice.

Отзывы: