Amana
Fayetteville, TN 37334
NOTE: It is important to electrically connect the unit
and properly size fuses/circuit breakers and wires in
accordance with all national and/or local electrical
codes. Use copper wire only.
Standard Features
• Bi-Flow Liquid Line Filter-Drier (Shipped Loose)
• Front Seating Valves
• Scroll Compressor
• 5 Minute Anti-Short Cycle Protection
• Automatic Reset High Pressure Switch
• Automatic Reset Loss Of Charge Switch
• Adaptive Demand Defrost
• Spring Loaded Check Valves
• Eight Pole Motor
• Dual Defrost Sensors
Accessories
• Fossil Fuel Kit (FFK03A)
• Compressor Sound Blanket (CSB08A)
• Ambient Temperature Kit (ATK05A)
• Hard Start Kit (HSK10A)
• Freeze Protector Kit (FSK01A)
(Installed on Indoor Coil)
NOTE: When mix matching with restrictor orifice indoor coil,
use restrictor orifice part number B1443808 or 11076306,
0.069 diameter.
Heat Pump Performance Data
For ARI Performance Data: See the ARI Directory, Product Data Booklet (PDB), or the product Service Manual.
August 1999
11070153
Above information is for nominal CFM and 70° F indoor dry bulb.
All pressures are PSIG.
All temperatures are °F.
Specifications
Cooling Capacity, BTUH (Nominal)
30,000
Compressor
R.L. Amps
13.5
L.R. Amps
72.5
Condenser Fan Motor
Horsepower
1/6
R.L. Amps
1.1
L.R. Amps
2.1
Liquid Line, Inches O.D.
3/8
Suction Line, Inches O.D.
3/4
Refrigerant Charge (oz)
189.5
Power Supply
208/230-60-1
Min Circuit Ampacity
18.1
Max Overcurrent Device
30.0
Electric Conduit Size (in)
Power Supply
1/2 or 3/4
Low Voltage
1/2
Approximate Shipping Weight (Lbs)
218
RHE30A2A / BHA30TB002A
Outdoor Ambient Temperature (° F)
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
∆
T
33
31
29
27
26
25
23
22
20
18
17
16
15
14
12
11
9
7
Amps
13.6 12.6 11.8 11.1 10.7 10.5
9.9
9.4
9.0
8.6
8.2
8.0
7.9
7.5
7.0
6.6
6.1
5.5
HI PR
252
242
232
222
217
213
205
196
188
180
173
168
165
159
153
147
141
136
LO PR
76
70
66
60
57
55
50
45
41
36
32
30
29
24
21
18
15
12
RHE30A2A
Remote Heat Pump
Specification Sheet
Due to policy of continual product improvement,
the right is reserved to change specifications and
design without notice.