background image

April 2000

Quiet Zone

Room Air Conditioner

Use And Care

Manual

 RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION

WARNING

To avoid death, personal injury or
property damage due to overheating, do
not leave this room air conditioner
unattended when used as cooling or life
support for persons or animals unable to
react to unit failure.  Take precautions to
warn or guard against such an
occurrence.

Please read this Use and Care Manual thoroughly.  This
manual provides proper maintenance information for maxi-
mum benefit of the features selected.

Contents

Electrical Requirements ........................................ 2

Electrical Grounding Instructions .................................. 2

Safety Features ...................................................... 2

Compressor Lockout ..................................................... 2
Low Voltage Protection .................................................. 2

Advantages of Amana’s Electronic Controls ....... 2
Operation ................................................................ 3

Vent Control ................................................................... 3
Unit Control .................................................................... 3

General Information .............................................. 6

Changing Air Flow Direction .......................................... 6
Air Flow Around Unit ...................................................... 6

Care and Maintenance .......................................... 6

Air Filter ......................................................................... 6

Before Calling For Service ................................... 7

Fan Motor ....................................................................... 7
Slide out Chassis ........................................................... 7

Model  Identification .............................................. 8
Any Questions? ...................................................... 8

                                         As an ENERGY STAR

® 

partner, AMANA

        APPLIANCES has determined that models

5M11TA, 5M11TB, 7M11TA, and 18M23TB meet the

 

ENERGY STAR

®

guidelines for energy efficiency.

Содержание Quiet Zone Room Air Conditioner

Страница 1: ... maintenance information for maxi mum benefit of the features selected Contents Electrical Requirements 2 Electrical Grounding Instructions 2 Safety Features 2 Compressor Lockout 2 Low Voltage Protection 2 Advantages of Amana s Electronic Controls 2 Operation 3 Vent Control 3 Unit Control 3 General Information 6 Changing Air Flow Direction 6 Air Flow Around Unit 6 Care and Maintenance 6 Air Filter...

Страница 2: ...e of the compressor a three minute time delay will occur when Electrical power is first supplied to the unit The thermostat is turned down immediately after the compressor stops running The Fan Control is quickly turned from FAN ONLY to COOLING mode or vice versa Low Voltage Protection This unit is equipped with brownout protection In case of an extreme brownout the Amana control will interrupt po...

Страница 3: ...ops cooling This feature can be used with SMART COOL or cooling with any fan speed Amana s new air sampling system works to maintain set temperature within 1 5 F while in ENERGY SAVER mode Approximately every 5 minutes the fan will turn on and sample theroomairtodetermineifcoolingisneeded Ifthe roomiscoolenough thefanwillcycleoff Iftheroomneeds further cooling the compressor will start along with ...

Страница 4: ... will flash 6Press the DELAY TIMER button to start the time or select nothing and the unit will start automati cally Button Note Changes can be made only while display is flashing You will have 5 seconds between each temperature operating mode and fan speed selection If a selection is not made during this time frame the unit will select the default and proceed to the next step Setting the delay ti...

Страница 5: ...ust be selected within a 5 second time period while flashing or the unit will select the default as the new setting If there is no loss of power the unit will keep the last setting Note If a power failure occurs the last delay settings will be lost and the default setting will be active Press the DELAY TIMER button to start the time or select nothing and the unit will start automati cally The disp...

Страница 6: ...anauthorizedservicer once a year to ensure proper function of the unit 1 Once a year remove chassis from outer case and thoroughly clean air conditioner 2 Washairconditionerwithwarm soapywaterasneeded Rinse and dry thoroughly 3 If using concentrated liquid detergent dilute in warm water first 4 DonotuseabrasivecleanerssuchasComet Ajax etc These items can scratch crack and discolor sur faces Oceans...

Страница 7: ...e Cause Suggested Solution Air conditioner will not operate No power to unit Set fan control to position other than off Confirm power cord is plugged in Check fuse or circuit breaker Little or no cooling Compressor lockout on initial plug in Wait 3 to 4 minutes and recheck compressor Dirty air filter Clean air filter Air conditioner undersized for application Check with dealer to determine proper ...

Страница 8: ...ing for Service section Any Questions Most of your questions can be answered by your local Amana dealer Check with your dealer first if you need any further information regarding the operation maintenance or service of your unit Then if you should have any matters which are not resolved locally or if you would like informa tion on other heating and cooling products or kitchen appliances offered by...

Страница 9: ......

Отзывы: