Amana NED7033W Скачать руководство пользователя страница 1

 Electric Dryer

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

NED7033W

Electrical

This dryer requires a 3 or 4 wire, single 

phase, 120/240 volt, 60 Hz, AC only electrical supply  

(or 3 or 4 wire, 120/208 volt electrical supply, if 

specified on the serial/rating plate) on a separate  

30-amp circuit, fused on both sides of the line.  

Connect to an individual branch circuit. Do not have 

a fuse in the neutral or grounding circuit.

Exhaust venting

Exhaust your dryer to the outside. 

4" (102 mm) diameter vent is required. Rigid or flexible 

metal exhaust vent must be used. Do not use plastic  

or metal foil vet. Exhaust hood must be at least  

12" (305 mm) from the ground or any object that  

may be in the path of the exhaust.

Hood styles: A & B are recommended.

   

4"

(102 mm)

2½"

(64 mm)

     

4"

(102 mm)

      

4"

(102 mm)

B

A

A. Louvered hood  
B. Box hood 
C. Angled hood (acceptable) 

C

Dryer dimensions

Select the route that will provide the straightest and 

most direct path outdoors.  

 

Plan the installation to use the fewest number of  

elbows and turns.  

 

Use the fewest 90° turns possible.

Because Whirlpool Corporation policy includes a continuous commitment to improve 

Dimensions are for planning purposes only. For complete details, see Installation 

our products, we reserve the right to change materials and specifications without notice. 

Instructions packed with product. Specifications subject to change without notice.

Ref. W10240579C 

11/2010

For closet installation, with a door, 

the minimum ventilation openings 

in the top and bottom of the door 

are required. Louvered doors with 

equivalent air ventilation openings 

are acceptable.

Do not use vent runs longer than specified in vent 

length chart.  

 

Determine the number of elbows you will need.

Most installations require a 

minimum 5" (127 mm) clearance   

behind the dryer for the exhaust 

vent with elbow. See “Venting  

Requirements.”

Vent system chart

Number of 

90° elbows

Type  

of vent

Box/louvered

hoods

Angled  

hoods

1

4

3

2

0

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Rigid metal

64 ft. (20 m)

54 ft. (16.5 m)

44 ft. (13.4 m)

35 ft. (10.7 m)

27 ft. (8.2 m)

58 ft. (17.7 m)

48 ft. (14.6 m)

38 ft. (11.6 m)

29 ft. (8.8 m)

21 ft. (6.4 m)

The Vent system chart provides venting requirements 

that will help achieve best drying performance.

NOTE:

 Side and bottom exhaust installation have a 90° 

turn inside the dryer. To determine maximum exhaust 

length, add one 90° turn to the chart. 

Minimum Required Spacing

27"

(686 mm)

1"

(25 mm)

35

3

/

8

"

(899 mm)

3

1

/

2

"

(89 mm)

29"

(736 mm)

Left or

 

right side 

exhaust

6

7

/

8

"

(174 mm)

1

5

/

8

"

(41 mm)

47

1

/

8

"

(1197 mm)

48

1

/

8

"

(1238 mm)

6

1

/

4

"

(159 mm)

28

1

/

8

"

(715 mm)

3

1

/

2

"

(89 mm)

14"

(358 mm)

Electric

1"

(25 mm)

1"

(25 mm)

4"

(102 mm)

7"

(178 mm)

18"

(460 mm)

1"

(25 mm)

1"

(25 mm)

5

1

/

2

"

(140 mm)

24 in.

2

(155 cm

2

)

48 in.

2

(310 cm

2

)

3"

(76 mm)

3"

(76 mm)

6"

(152 mm)

76"

(1930 mm)

1"

(25 mm)

1"

(25 mm)

39" min.

(990 mm)

24 in.

2

(155 cm

2

)

48 in.

2

(310 cm

2

)

1"

(25 mm)

1"

(25 mm)

4"

(102 mm)

3"

(76 mm)

34" recommended

(864 mm)

18" min.

(457 mm)

3"

(76 mm)