5.92
Automatic display brightness
Section:
dISP
Display:
brgt Auto
Range:
OFF
or
ON
Default Value:
On
Default Access Level
2
Function number
22FC
Automatic display brightness adjustment. Applies only to instruments with light sensor fitted. The automatic
brightness adjustment uses the optional light sensor to gauge the required brightness level for the environment. The
high and low brightness limits are set at the
Auto HiGh
and
Auto Lo
functions described below.
5.93
Display brightness
Section:
dISP
Display:
brgt
Range:
1
to
64
Default Value:
63
Default Access Level
2
Function number
22Fb
Allows manual adjustment of the display brightness from 1 (lowest brightness) to 63 (highest brightness).
5.94
Dimmed display brightness
Section:
dISP
Display:
duII
Range:
0
to
63
Default Value:
7
Default Access Level
2
Function number
22EC
Displays and sets the manually set level for remote input brightness switching. When a remote input is set to
duII
the remote input can be used to switch between the display brightness level set by the
brgt
function and
the dimmed display brightness set by the
duII
function. The display dull level is selectable from
0
to
63
, where
0
= lowest intensity and
63
= highest intensity. This function is useful in reducing glare when the display needs to
be viewed in both light and dark ambient light levels.
5.95
Auto display brightness high level
Section:
dISP
Display:
Auto High
Range:
16
to
64
Default Value:
63
Default Access Level
2
Function number
22EA
Automatic brightness high level - seen only when
brgt Auto
is set to
ON
. The high brightness level sets the
maximum brightness which the automatic brightness control can achieve with 64 being the highest intensity.
60 of
LD5RSMAN-2.0-0