Chapter
4
72
ML-7 Series/ML-9001A
Chapter
4
Maintenance
The Control Unit includes a lithium backup battery. If this battery runs out, settings in the memory will be
lost when the Main Switch of the Control Unit is turned off. To prevent this, purchase a new battery from
us and replace the battery under either of the following conditions:
•
Three years have passed since battery replacement
•
Within one week after the first indication of battery errors
■
ML-7111A and ML-9001A
Have the following items ready when replacing the lithium battery of the ML-7111A and ML-9001A:
•
Lithium battery (new)
•
Hex wrench
•
Phillips screwdriver
1
About 30 minutes before replacing the
battery, turn on the Main Switch of the
Control Unit to activate the battery.
This step is required to charge the
internal power supply, which is used for
data storage during battery replacement.
You may skip this step if the marker has
already been in use for more than 30
minutes.
2
On the Control Unit, turn off the main
switch.
3
Unscrew the six screws on the sides of
the Control Unit.
4
Remove the carrying handle by
unscrewing the four hex screws on top
of the Control Unit on both sides.
5
Remove the cover by sliding it back about 15 mm and lifting it up.
4.8 Backup Lithium Battery Replacement
Follow your local environmental regulations for battery disposal, as the lithium battery
contains potentially harmful substances.
Four hex screws on both sides
Carrying handle
Slide the cover back
about 15 mm, then
lift it.
Cover
Six screws (M3) on both sides
Control Unit, side view
Содержание ML-7 Series
Страница 1: ...Installation Maintenance Z11OM1158223 20 LD Pumped Laser Marker ML 7 Series ML 9001A OPERATION MANUAL...
Страница 4: ......
Страница 8: ...4 ML 7 Series ML 9001A Contents...
Страница 43: ...Chapter 4 39 ML 7 Series ML 9001A 4 3 Air Filter Inspection and Replacement 5 Attach the air filter cover...
Страница 82: ...Chapter 4 78 ML 7 Series ML 9001A Chapter 4 Maintenance...
Страница 83: ...Appendix...