Chapter
4
57
ML-7 Series/ML-9001A
4.5 FC-LD (Oscillation Unit) Inspection and Replacement
■
ML-7064A (Oscillation Unit Attachment)
Have the following items ready when replacing the Oscillation Unit of the ML-7064A:
•
Phillips screwdriver
•
Screwdriver
•
Hex wrench
1
Remove the head CN3 shorting
connector from the CN3 connector at the
back of the Oscillation Unit after
loosening the fastening screw.
2
Holding the handles, lift the Oscillation Unit. With the pinholes at the bottom of the Oscillation Unit
aligned with the positioning pins of the Head Unit, attach the Oscillation Unit and Head Unit.
Perform this step very carefully to avoid any impact to the Oscillation Unit.
3
Remove the handles.
4
Reattach the three bolts that were removed when detaching the Oscillation Unit.
Head CN3 shorting connector
(provided)
Fastening screw
Oscillation Unit positioning pins
Align the pinholes at the bottom of the
Oscillation Unit with these positioning
pins, then attach the units.
Attach them carefully, avoiding any
sudden impacts.