Chapter
4
35
ML-7 Series/ML-9001A
4.2 Part Replacement Schedule
*1 This maintenance schedule provides guidelines based on 8 hours of operation per day.
*2 Replace components at the end of their useful life or if they burn out or become defective.
*3 Extended periods of non-use will shorten the useful life of the marker.
*4 For the ML-7064A, the maintenance schedule involves annual cleaning or replacement.
*5 For the ML-7064A, the maintenance schedule is as follows: daily cleaning/replacement every year.
*6 For the ML-7064A, the maintenance schedule involves cleaning or replacement every two years.
*7 Repeated marking in a very small area may damage the scanner bearings and shorten their useful life. We
recommend marking a wide area at least once per day.
*8 For the ML-7064A, the maintenance schedule involves replacement every two years.
*9 Replace these components regularly regardless of how much the marker is used.
f
lens
protective
glass
f350
Daily
(5 years)
(*5)
Clean
(replace)
-
-
-
1159500
f410
-
-
1159505
-
f420
1029246
-
-
-
Resonator unit
3 years
Replace or
repair
1011188
1011269
1011148
-
Oscillation Unit
At the end of
its useful life
Replace
-
-
-
1010962
Beam
expander
1.5x
5 years
(*6)
Replace
1029546
-
1029552
-
2x
1029545
-
1029551
-
3x
1029541
-
1029547
1029541
4x
1029542
-
1029548
1029542
6x
1029543
-
1029549
1029543
8x
1029544
-
1029550
1029544
Scanner unit
(*7)
X scanner
10
10
cycles
(5 years)
(*8)
Replace
1014546
1029658
1014548
1014582
Y scanner
1014547
1029657
1014549
1014581
Driver
1 per shaft
1029642
-
1029642
-
Optical fiber
3 m
2 years
Replace
1029344
1029344
1029344
-
5 m
1029345
-
1029345
-
8 m
1029346
-
1029346
-
10 m
1029347
-
1029347
-
Graphite sheet
When the
FC-LD is
replaced
Replace
1039583
1039583
1039583
-
LBO
New
2 years
Replace
-
-
1028647
-
FC-LD
New
At the end of
its useful life
Replace
1011136
1011290
1011136
-
Refurbished
1011137
1011342
1011137
-
Coolant (*9)
3 months
Replace
-
-
-
1010677
Coolant filter (*9)
6 months
Replace
-
-
-
1163529
Chiller Unit
2 years
Replace
-
-
-
1011419
Ion-exchange resin (*9)
3 to 6 months
Replace
-
-
-
1039568
Protective eyewear
-
Replace
1171397
1171397
1151777
1171397
Plug (Oscillator base)
3 years
Replace
-
-
-
1032476
Component
Schedule
(*1)
Maintenance
(*2)
Part Number
ML-7111A
ML-7112AH
ML-9001A
ML-7064A
Содержание ML-7 Series
Страница 1: ...Installation Maintenance Z11OM1158223 20 LD Pumped Laser Marker ML 7 Series ML 9001A OPERATION MANUAL...
Страница 4: ......
Страница 8: ...4 ML 7 Series ML 9001A Contents...
Страница 43: ...Chapter 4 39 ML 7 Series ML 9001A 4 3 Air Filter Inspection and Replacement 5 Attach the air filter cover...
Страница 82: ...Chapter 4 78 ML 7 Series ML 9001A Chapter 4 Maintenance...
Страница 83: ...Appendix...