1. Control Method
59
ML-2550A/2551A
Chapter 1 Control Method, and Start and Stop
Introduction Part
Inst
allat
ion and
Preparation Part
Operating Part
Maintenance Part
Appendixes
Chapter 1
●
Control Method, and Start and Stop
1. Control Method
This section explains the control method for the laser.
The following 3 control methods are available, namely, control from the laser
controller (PANEL CONTROL), control by external input/output signals connecting
the PLC (*) to the laser (EXTERNAL CONTROL), and control by sending commands
from the personal computer or the like (RS-485 CONTROL).
Select one of these 3 control methods according to the welding work. The selected
control method is displayed on the STATUS screen.
*: PLC: Programmable Logic Controller which is a unit to perform sequence control by executing the
programmed contents of control in sequence. This unit is often called sequencer (product name of
Mitsubishi Electric Corporation).
Switching the Control Method
Control by Laser Controller (PANEL CONTROL)
When the laser is used independently or when the power supply of the PLC or
personal computer connected to the laser is OFF, the laser is under control by laser
controller.
⇒
To switch the control by external input/output signals over to the control by laser
controller, turn OFF pin No.23 (control switching) of the EXT. I/O (1) connector.
⇒
To switch the control by external communication control over to the control by
laser controller, send a command to set the control method from the personal
computer.
⇒
If the CONTROL keyswitch of the main unit is turned OFF even if another control
method is used, it is reset to the control by laser controller. When the CONTROL
keyswitch is turned on again, the control method is switched to the control from
the laser controller if the external communication control is used, or the control
method is set to the control by external input/output signals if the control by
external input/output signals is used and Pin No.23 (control switching) of the
EXT. I/O (1) connector is ON (closed circuit).
Control by External Input/Output Signals (EXTERNAL CONTROL)
When the PLC or the like is connected to the main unit and pin No.23 (control
switching) of the EXT.I/O (1) connector is turned ON (closed circuit), the control by
external input/output signals (EXTERNAL CONTROL) is selected.
⇒
This control method cannot be selected by operating the laser controller or
personal computer.
Operating Part
Содержание ML-2550A
Страница 1: ...AA06M0642E 37 OPERATION MANUAL YAG LASER WELDER ML 2550A 2551A...
Страница 19: ...Introduction Part...
Страница 20: ......
Страница 37: ...Installation and Preparation Part...
Страница 38: ......
Страница 46: ......
Страница 57: ...Operating Part...
Страница 58: ......
Страница 116: ......
Страница 144: ......
Страница 168: ......
Страница 173: ...Maintenance Part...
Страница 174: ......
Страница 203: ...Appendixes...
Страница 204: ......