Up to 16 laser units can be controlled from a single personal computer . The
equipment configuration and
connector connections are shown in the follow-
ing figure.
⇒
For controlling multiple lasers by single personal computer, it is necessary to reg-
ister equipment No. (NETWORK #) for each equipment. Set equipment No. with-
out duplication. If duplication of equipment No. exists, a data collision will occur
on the communication line and the laser cannot be correctly operated.
⇒
The RS-232C/RS-485 conversion adapter is an option separately sold. Purchase
it as required. For details, refer to the Introduction Part, Chapter 1 "Options" on
page 28.
⇒
Prepare the program and its development environment for laser control on the
customer side.
⇒
It is recommended to use the shielded cable. To exhibit the shield effect, connect
the shield of a cable to FG (frame ground) inside the laser equipment. Do not
use it as SG (signal ground).
A
B
C
D
E
TxD+
TxD-
RxD+
RxD-
TxD+
TxD-
RxD+
RxD-
A
B
C
D
E
TxD+
TxD-
RxD+
RxD-
TxD+
TxD-
RxD+
RxD-
←RxD
TxD→
RS-232C
RS-232C/RS-485 conversion adapter
RS-485
RS-485
RS-485
Up to 16 units
Equipment No.00
Equipment No.01
Equipment No.15
Personal computer, etc.
Connection example
RS-232C/RS-485
conversion adapter
Inside of the
laser equipment
RS-232C/RS-485
conversion adapter
Inside of the
laser equipment
Connector 116-21A10-5M
Connector
116-21A10-5M
FG
FG
The representation of + and - for signal lines may
be reversely indicated. If communication fails, try
to r and - each other.
Содержание MF-C300A-SF
Страница 1: ...AA03OM1193140 12 FIBER LASER WELDER MF C300A SF C500A SF OPERATION MANUAL Original instructions...
Страница 20: ......
Страница 21: ...Introduction Part...
Страница 22: ......
Страница 36: ......
Страница 37: ...Installation and Preparation Part...
Страница 38: ......
Страница 42: ......
Страница 50: ......
Страница 51: ...Operating Part...
Страница 52: ......
Страница 114: ......
Страница 159: ...Maintenance Part...
Страница 160: ......
Страница 176: ......
Страница 177: ...Appendixes...
Страница 178: ......
Страница 182: ...182 MF C300A SF C500A SF Dimensional Outline Drawings Fiber Connector Unit mm Max diameter incl the removable gaiter...